In one paragraph

Article in Magnetic resonance in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Feasibility of tagged MRI at 0.55 T.Magnetic resonance in medicine · 2026
    Article
  6. Article
  7. Simultaneous multi-slice cardiac real-time MRI at 0.55T.Magnetic resonance in medicine · 2025
    Article
  8. Quantification of exercised-induced myocardial deformation with exercise CMR.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ecrin YagizMing Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA.ORCID 0000-0001-8113-2192
Parveen GargDivision of Cardiology, Department of Medicine, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
Steven Y CenDepartment of Neurology, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
Krishna S NayakMing Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA.ORCID 0000-0001-5735-3550
Ye TianMing Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA.ORCID 0000-0002-8559-4404

Funding

Volumetric Real-Time MRI at 0.55 TeslaU01HL167613 · NHLBI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI Adrienne Campbell, Krishna Shrinivas Nayak · 2023 to 2026
$2.0M
Improved Myocardial Perfusion Assessment using High-Performance Low-Field MRIR21HL159533 · NHLBI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI NAYAK, KRISHNA S · 2022 to 2023
$454k
NHLBI NIH HHS R21 HL159533NHLBI NIH HHS U01 HL167613NIH HHS R21-HL159533NIH HHS U01-HL167613
6 · The paper itself

Abstract

purposeTo determine the feasibility of simultaneous multi-slice (SMS) real-time MRI (RT-MRI) at 0.55T for the evaluation of cardiac function.

methodsCardiac CINE MRI is routinely used to evaluate left-ventricular (LV) function. The standard is sequential multi-slice balanced SSFP (bSSFP) over a stack of short-axis slices using electrocardiogram (ECG) gating and breath-holds. SMS has been used in CINE imaging to reduce the number of breath-holds by a factor of 2-4 at 1.5T, 3T, and recently at 0.55T. This work aims to determine if SMS is similarly effective in the RT-MRI evaluation of cardiac function. We used an SMS bSSFP pulse sequence with golden-angle spirals at 0.55T with an SMS factor of three. We cover the LV with three acquisitions for SMS, and nine for single-band (SB). Imaging was performed on 9 healthy volunteers and 1 patient with myocardial fibrosis and sternal wires. A spatio-temporal constrained reconstruction is used, with regularization parameters selected by a board-certified cardiologist. Images were quantitatively analyzed with a normalized contrast and an Edge Sharpness (ES) score.

resultsThere was a statistically significant 2-fold difference in contrast between SMS and SB and no significant difference in ES score. The contrast for SMS and SB were 13.38/29.05 at mid-diastole and 10.79/22.26 at end-systole; the ES scores for SMS and SB were 1.77/1.83 at mid-diastole and 1.50/1.72 at end-systole.

conclusionsSMS cardiac RT-MRI at 0.55T is feasible and provides sufficient blood-myocardium contrast to evaluate LV function in three slices simultaneously without any gating or periodic motion assumptions.

Indexed as

HeartMagnetic Resonance Imaging, CineAdultAlgorithmsFeasibility StudiesFemaleHeart VentriclesHumansImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedMaleMiddle AgedReproducibility of Results0.55 tesla MRIcardiac functionreal‐time MRIsimultaneous multi‐slice

Identifiers

PMID39506513
PMCPMC11782716

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.