Evidence map›Paper›PMID 39504280›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2024

High-Frequency Wearable Ultrasound Array Belt for Small Animal Echocardiography.

Yushun Zeng, Xin Sun, Junhang Zhang, Chi-Feng Chang, Baoqiang Liu, Chen Gong, Jie Ji, Bryan Zhen Zhang, Yujie Wang, Matthew Xinhu Ren and 3 more

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Yushun Zeng
Xin Sun
Junhang Zhang
Chi-Feng Chang
Baoqiang Liu
Chen Gong
Jie Ji
Bryan Zhen Zhang
Yujie Wang
Matthew Xinhu Ren
Robert Wodnicki
Hsiao-Chuan Liu
Qifa Zhou

Funding

High-Resolution Flow Imaging of Optic Nerve Head and Retrolaminar Microvascular CirculationR01EY035084 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI Shigao Chen, Qifa Zhou · 2023 to 2026
$2.7M
Biomechanical mapping of the optic nerve head and peripapillary sclera using high frequency ultrasonic elastographyR01EY032229 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI ZHOU, QIFA · 2021 to 2024
$2.6M
Sonogenetic Restoration of Vision for Retinitis PigmentosaU01EY035026 · NEI · NANOSCOPE TECHNOLOGIES, LLC · PI Samarendra Kumar Mohanty, Qifa Zhou · 2024 to 2026
$2.4M
Non-invasive Ultrasound Stimulated Retinal ProsthesisR01EY030126 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI ZHOU, QIFA · 2019 to 2022
$2.0M
Development of two-dimensional (2D) acoustic force elastography microscopy for the non-contact measurement of elastic property of cell encapsulated scaffoldsR21GM154167 · NIGMS · UNIVERSITY OF SOUTHERN CALIFORNIA · PI LIU, HSIAO-CHUAN · 2024 to 2025
$410k
Wearable Array for Ultrasound Stimulation on the RetinaR41EY035609 · NEI · PHONONZ INC · PI CHABOK, HAMID REZA, ZHOU, QIFA · 2023 to 2023
$276k
Development of non-contact rheometry for measuring rheological properties of biological fluidsR03EB032958 · NIBIB · UNIVERSITY OF SOUTHERN CALIFORNIA · PI LIU, HSIAO-CHUAN · 2022 to 2023
$165k
NEI NIH HHS R01 EY030126NEI NIH HHS R01 EY032229NEI NIH HHS R01 EY035084NEI NIH HHS R41 EY035609NEI NIH HHS U01 EY035026NIBIB NIH HHS R03 EB032958NIGMS NIH HHS R21 GM154167
6 · The paper itself

Abstract

Wearable ultrasound has been widely developed for long-term, continuous imaging without the need for bulky system manipulation and repeated manual locating. To potentially lead to more accurate and reliable imaging monitoring, this work presents the design, fabrication, and evaluation of a novel high-frequency wearable ultrasound array belt (WUAB) for small animal echocardiography. The fabrication process involved precise dicing technology for a -pitch design. The WUAB consists of two matching layers, a piezoelectric composite with 128 channels, a customized flexible circuit substrate, an acoustic backing layer, and a customized belt structure with designed end tip and insertion point for wearability. The resulting WUAB demonstrates the sensitivity of and the fractional bandwidth (BDW) of . In vivo experiments on rat model showed expected echocardiography and B-mode images of rat heart. These results represent significant promise for future longitudinal studies in small animals and real-time physiological monitoring.

Indexed as

EchocardiographyWearable Electronic DevicesAnimalsEquipment DesignHeartRatsRats, Sprague-DawleyTransducers

Identifiers

PMID39504280
PMCPMC12077870

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.