Evidence map›Paper›PMID 39503992›Full record

ArticleOphthalmology and therapy2025

Diagnostic Accuracy of Automated Diabetic Retinopathy Image Assessment Software: IDx-DR and RetCAD.

Andrzej Grzybowski, Piotr Brona, Tomasz Krzywicki, Paisan Ruamviboonsuk

Abstract read
In one paragraph

Article in Ophthalmology and therapy, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Artificial intelligence in diabetic retinopathy: from automated screening to risk-stratified care.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
    Review
  2. Observational
  3. Review
  4. Article
  5. Review
  6. A Review of Recent Developments in Artificial Intelligence and Big Data Technologies for Ophthalmology Referrals and Clinical Practice.Medical science monitor : international medical journal of experimental and clinical research · 2026
    Review
  7. Review
  8. Review
  9. Article
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Andrzej GrzybowskiInstitute for Research in Ophthalmology, Foundation for Ophthalmology Development, Poznan, Poland. ae.grzybowski@gmail.com.ORCID http://orcid.org/0000-0002-3724-2391
Piotr BronaDepartment of Ophthalmology, Poznan City Hospital, Szwajcarska 3, 60-285, Poznan, Poland.
Tomasz KrzywickiDepartment of Mathematical Methods of Informatics, University of Warmia and Mazury, Olsztyn, Poland.
Paisan RuamviboonsukDepartment of Ophthalmology, Rajavithi Hospital, College of Medicine, Rangsit University, Bangkok, Thailand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAutomated diabetic retinopathy (DR) screening using artificial intelligence has the potential to improve access to eye care by enabling large-scale screening. However, little is known about differences in real-world performance between available algorithms. This study compares the diagnostic accuracy of two AI screening platforms, IDx-DR and RetCAD, for detecting referable diabetic retinopathy (RDR).

methodsRetinal images from 758 patients with diabetes were collected during screening from various clinics in Poland. Each patient was graded by three graders with 320 patients graded by Polish and 438 patients graded by Indian graders, with the majority decision serving as the reference standard. The images were evaluated independently by the IDx-DR and RetCAD algorithms. Sensitivity, specificity, positive and negative predictive values, and agreement between algorithms and human graders were calculated and statistically compared.

resultsIDx-DR demonstrated higher sensitivity of 99.3% but lower specificity of 68.9% for RDR detection compared to RetCAD which had 89.4% sensitivity and 94.8% specificity. The positive predictive value was higher for RetCAD (96.4% vs 48.1% for IDx-DR) while the negative predictive value was higher for IDx-DR (99.5% vs 83.1% for RetCAD). Both algorithms achieved high sensitivity (> 95%) for sight-threatening diabetic retinopathy detection.

conclusionIn this direct comparison using the same patient cohort, the two algorithms showed differences in their operating parameters for RDR screening. IDx-DR prioritized avoiding false negatives over false positives while RetCAD maintained a more balanced trade-off. These results highlight the variable performance of current artificial intelligence screening solutions and suggest the importance of considering algorithm performance metrics when deploying automated diabetic retinopathy screening programs, based on available healthcare resources.

Indexed as

Artificial intelligenceDiabetic retinopathyDiagnosticImageScreening

Identifiers

PMID39503992
PMCPMC11724818

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.