Evidence map›Paper›PMID 39502678›Full record

ArticleJournal of orthopaedics2025

Accuracy of total knee arthroplasty using hospital-based 3D printed patient-specific instrumentation: A radiology research.

Vo Sy Quyen Nang, Pham Trung Hieu, Vu Tu Nam, Tran Trung Dung, Duong Dinh Toan

Abstract read
In one paragraph

Article in Journal of orthopaedics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. [Study on influence of tooth-supported osteotomy guide plates on the accuracy of mandibular segmental resection and its surgical outcome].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Vo Sy Quyen NangHanoi Medical University, Hanoi, Viet Nam.
Pham Trung Hieu3D Technology in Medicine Center, VinUniversity, Hanoi, Viet Nam.
Vu Tu Nam3D Technology in Medicine Center, VinUniversity, Hanoi, Viet Nam.
Tran Trung DungCenter for Orthopaedic and Sport Medicine, Vinmec Healthcare System, Hanoi, Viet Nam.
Duong Dinh ToanHanoi Medical University, Hanoi, Viet Nam.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Patient-specific instruments (PSIs) were reported to improve implant position and rotation accuracy in total knee arthroplasty (TKA), among other benefits. Most PSIs used in TKA were commercial products from implant manufacturers, which could be time-consuming and could potentially affect accuracy as they relied on engineer's decision. This study aimed to present the radiological outcomes of PSI produced by the 3D printing facility at our hospital, with direct involvement of the surgeon in its design. Methods: This prospective study enrolled 45 patients who underwent mechanically aligned TKA. Preoperative whole-limb 3D-CT scans were obtained to create the sizing plan. The surgeon identified the position of the cut plane and guide pin locations on software, which were then forwarded to engineers for further processing. Subsequently, the PSI was fabricated using in-hospital 3D resin printers. During surgery, after removing all remaining cartilage, the PSI was utilized on the bone surfaces to assist surgeons in drilling pinhole positions for the manufacturer's cutting instruments. Post-surgery, CT scans were acquired and overlaid onto the 3D model of the implant to compare to the plan. Results: On average, it took three days to prepare for the surgery using PSI. 100 % of patients had implant sizes that matched the preconception template. The mean postoperative hip-knee angle was 178.1° ± 1.34°. The mean femoral component rotation angle relative to the surgical transepicondylar axis (sTEA) and the mean rotation mismatch between the femur and tibial component were 0.99° ± 0.84° and 0.91° ± 1.61°, respectively. Conclusions: Preliminary radiological results demonstrated that in-hospital PSI was a useful technique for improving the accuracy of implant positioning in TKA, especially in controlling the rotational alignment.

Indexed as

3D printingIn-hospital 3D printingPatient-specific instrumentationPSITKATotal knee arthroplasty

Identifiers

PMID39502678
PMCPMC11532799

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked