Evidence map›Paper›PMID 39502261›Full record

ArticleEuropean heart journal. Case reports2024

Use of suture-mediated closure device system after inadvertent medport placement in the subclavian artery leading to multi-focal ischaemic infarct: a case report.

María A Rodríguez-Santiago, Edwin Rodríguez-Cruz, Marcel A Mesa-Pabon

Abstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

María A Rodríguez-SantiagoDivision of Cardiology, Department of Internal Medicine, University of Puerto Rico, Medical Sciences Campus, School of Medicine, PO Box 365067, San Juan, PR 00936-5067, USA.ORCID https://orcid.org/0000-0002-8848-3013
Edwin Rodríguez-CruzCardiovascular Center of Puerto Rico and the Caribbean, PO Box 366528, San Juan, PR 00936-6528, USA.
Marcel A Mesa-PabonDivision of Cardiology, Department of Internal Medicine, University of Puerto Rico, Medical Sciences Campus, School of Medicine, PO Box 365067, San Juan, PR 00936-5067, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Totally implantable venous access devices or chemoports are progressively being used in oncologic patients for long-term chemotherapy administration. We present the case of an iatrogenic arterial catheter placement in the aortic arch complicated with multi-focal ischaemic stroke. Case summary: A case of a 73-year-old woman with a history of hypertension, diabetes mellitus, pineal gland tumour status post ventriculoperitoneal shunt, and breast and bladder cancer presented with a 2-week history of impaired balance, dysarthria, and right-sided facial drop. The chemoport was placed less than a month prior to the onset of symptoms at another institution. A brain magnetic resonance imaging revealed a left hemispheric supra- and infra-tentorial subacute ischaemic infarcts. The head and neck computed tomography angiography notably showed a misplaced venous port at the left subclavian artery with a distal tip projecting towards the ascending aortic arch, revealing the most likely aetiology of multi-focal ischaemic stroke. The patient underwent successful subclavian artery catheter extraction and endovascular repair with a suture-mediated closure device system without complications. Discussion: Subclavian artery iatrogenic cannulation may lead to catastrophic outcomes, including stroke. A high level of suspicion for venous port misplacement must be entertained when ipsilateral multi-focal ischaemic infarct occurs in time relation to catheter placement. Conducting an endovascular catheter retrieval and using a suture-mediated closure device is an alternative approach to manual compression in locations where achieving an haemostasis is challenging. A suture-mediated closure device system might be useful for anatomy not amenable to manual compression, such as the subclavian artery.

Indexed as

Case reportChemoportEndovascular catheter retrievalMulti-focal ischaemic strokeSubclavian artery iatrogenic cannulation

Identifiers

PMID39502261
PMCPMC11536085

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.