Evidence map›Paper›PMID 39501083›Full record

ArticleNPJ digital medicine2024

Deep learning based highly accurate transplanted bioengineered corneal equivalent thickness measurement using optical coherence tomography.

Daewoon Seong, Euimin Lee, Yoonseok Kim, Che Gyem Yae, JeongMun Choi, Hong Kyun Kim, Mansik Jeon, Jeehyun Kim

Abstract read
In one paragraph

Article in NPJ digital medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Daewoon Seong *School of Electronic and Electrical Engineering, College of IT engineering, Kyungpook National University, Daegu, Republic of Korea.
Euimin Lee *School of Electronic and Electrical Engineering, College of IT engineering, Kyungpook National University, Daegu, Republic of Korea.
Yoonseok KimSchool of Electronic and Electrical Engineering, College of IT engineering, Kyungpook National University, Daegu, Republic of Korea.
Che Gyem YaeBio-Medical Institute, Kyungpook National University Hospital, Daegu, Korea.
JeongMun ChoiBio-Medical Institute, Kyungpook National University Hospital, Daegu, Korea.
Hong Kyun KimBio-Medical Institute, Kyungpook National University Hospital, Daegu, Korea. okeye@knu.ac.kr.
Mansik JeonSchool of Electronic and Electrical Engineering, College of IT engineering, Kyungpook National University, Daegu, Republic of Korea. msjeon@knu.ac.kr.ORCID http://orcid.org/0000-0002-0630-9039
Jeehyun KimSchool of Electronic and Electrical Engineering, College of IT engineering, Kyungpook National University, Daegu, Republic of Korea.

Funding

Ministry of Science, ICT and Future Planning (MSIP) IITP-2024-RS-2022-00156389Ministry of Science, ICT and Future Planning (MSIP) NRF-2021R1A2C2013939
6 · The paper itself

Abstract

Corneal transplantation is the primary treatment for irreversible corneal diseases, but due to limited donor availability, bioengineered corneal equivalents are being developed as a solution, with biocompatibility, structural integrity, and physical function considered key factors. Since conventional evaluation methods may not fully capture the complex properties of the cornea, there is a need for advanced imaging and assessment techniques. In this study, we proposed a deep learning-based automatic segmentation method for transplanted bioengineered corneal equivalents using optical coherence tomography to achieve a highly accurate evaluation of graft integrity and biocompatibility. Our method provides quantitative individual thickness values, detailed maps, and volume measurements of the bioengineered corneal equivalents, and has been validated through 14 days of monitoring. Based on the results, it is expected to have high clinical utility as a quantitative assessment method for human keratoplasties, including automatic opacity area segmentation and implanted graft part extraction, beyond animal studies.

Identifiers

PMID39501083
PMCPMC11538249

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.