Evidence map›Paper›PMID 39500776›Full record

ArticleClinical oral investigations2024

The effect of various denture cleansers on the physical and mechanical properties of CAD/CAM and heat-polymerized denture base materials: an in vitro study.

Ozyurt Tekin Selin, Caglar Ipek

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical oral investigations, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Ozyurt Tekin SelinDepartment of Prosthodontics, Faculty of Dentistry, Recep Tayyip Erdogan University, Islampasa, Menderes Blvd. No:612 Rize, Rize, 53020, Turkey.ORCID 0000-0002-1338-8329
Caglar IpekDepartment of Prosthodontics, Faculty of Dentistry, Recep Tayyip Erdogan University, Islampasa, Menderes Blvd. No:612 Rize, Rize, 53020, Turkey. ipek.caglar@erdogan.edu.tr.ORCID 0000-0002-2286-4657

Funding

Recep Tayyip Erdogan Üniversitesi Grant No: TDH-2021-1313
6 · The paper itself

Abstract

objectivesTo investigate the effects of denture cleansers on the various properties of CAD/CAM and heat-polymerized polymethyl methacrylate (PMMA). MATERIALS AND

methodsTwo different brands of heat-polymerized and two of milled PMMA were fabricated (n = 50), in total 200. Each group was randomly divided into five subgroups (n = 10): control groups (D1) kept in distilled water, cleaning tablets (D2, D3), neutral (D4) and acidic electrolyzed acid water (EAW) (D5). Surface roughness, hardness and flexural strength values were evaluated. Data were statistically analyzed with two-way ANOVA and Tukey post hoc test for comparison (p<0.05).

resultsThe milled group showed significantly lower surface roughness, greater surface hardness, and higher flexural strength values than heat polymerized denture bases (p<0.05). The denture cleansers had no significant effect on the surface roughness values of the milled specimens (p>0.05), whereas the specimens in the heat-polymerized groups and treated with D5 showed greater surface roughness values compared with the other cleaning agents (p > 0.05). The denture cleansers had no significant effect on surface hardness and flexural strength of heat polymerize groups (p > 0.05). However, D2, D3 and D5 cleaning agent decreased the hardness values of the milled group (p<0.05) and D5 cleaning agent decreased the flexural strength of the milled group (p<0.05).

conclusionsIt was observed that the applied denture cleansers affected the surface roughness, surface hardness, and flexural strength values of both denture bases but within a clinically acceptable value. CLINICAL RELEVANCE: CAD/CAM denture bases showed significantly higher physical and mechanical properties than to heat-polymerized base materials. Although the applied neutral EAW cleaners give desired results for denture bases, clinical studies are needed for biological compatibility.

Indexed as

Computer-Aided DesignDenture CleansersFlexural StrengthPolymethyl MethacrylateSurface PropertiesDental MaterialsDenture BasesHot TemperatureHumansIn Vitro TechniquesPolymerizationDental MaterialsDenture CleansersPolymethyl MethacrylateAcrylic resinCAD/CAMDenture basesDenture cleansersFlexural strength

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.