Evidence map›Paper›PMID 39500751›Full record

ArticleScientific reports2024

Possibilities and limitations of computer assisted chiral HPLC method development for ozanimod on polysaccharide based chiral stationary phases.

Elek Ferencz, Zoltán-István Szabó, Arnold Zöldhegyi, Gergely Dombi, Gergely Molnár, Máté Dobó, Erzsébet Varga, Imre Molnár, Gergő Tóth

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Elek Ferencz *George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Târgu Mureş, Romania.
Zoltán-István Szabó *George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Târgu Mureş, Romania.
Arnold ZöldhegyiMolnár-Institute for Applied Chromatography, Berlin, Germany.
Gergely DombiDepartment of Pharmaceutical Chemistry, Semmelweis University, Hőgyes E. u. 9, Budapest, 1092, Hungary.
Gergely MolnárDepartment of Pharmaceutical Chemistry, Semmelweis University, Hőgyes E. u. 9, Budapest, 1092, Hungary.
Máté DobóDepartment of Pharmaceutical Chemistry, Semmelweis University, Hőgyes E. u. 9, Budapest, 1092, Hungary.
Erzsébet VargaGeorge Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Târgu Mureş, Romania.
Imre MolnárMolnár-Institute for Applied Chromatography, Berlin, Germany.
Gergő TóthDepartment of Pharmaceutical Chemistry, Semmelweis University, Hőgyes E. u. 9, Budapest, 1092, Hungary. toth.gergo@semmelweis.hu.

Funding

Magyar Tudományos Akadémia János Bolyai Research ScholarshipNational Research, Development and Innovation Office NKFIH FK 146930Nemzeti Kutatási, Fejlesztési és Innovaciós Alap ÚNKP-23-2-IIINemzeti Kutatási, Fejlesztési és Innovaciós Alap ÚNKP-23-3-II
6 · The paper itself

Abstract

In this study, a direct HPLC method was developed to determine the enantiomeric purity of the immunomodulatory drug, ozanimod. A systematic method development process was followed, incorporating risk assessment, identification of critical analytical procedure parameters, initial screening of stationary phases, and software-assisted optimization of method parameters. Eight different polysaccharide-based chiral columns were selected to assess chiral separation of enantiomers under polar organic elution mode. The most promising results were obtained using a methanol:2-propanol mixture on the amylose-based Chiralpak AD column. Following this, systematic modeling was conducted using DryLab software to optimize method conditions, including isocratic eluent composition, temperature, and flow rate. Baseline separation was achieved within fifteen minutes using the optimized parameters: Chiralpak AD column thermostated at 10 °C, and a mobile phase of methanol:2-propanol: diethylamine, 70:30:0.1 (v/v/v %), delivered at a flow rate of 0.8 mL/min. The developed method was validated according to current guidelines and in silico robustness testing was conducted to determine tolerance limits for critical separation parameters and their impact on enantioresolution. Our findings demonstrate the utility of DryLab, typically employed for reversed-phase achiral separations, in optimizing chiral methods even in polar organic mode. Limitations of the selected approach the development of chiral separation methods are also highlighted.

Indexed as

Polysaccharides2-PropanolAmyloseChromatography, High Pressure LiquidMethanolPhenylcarbamatesSoftwareStereoisomerism2-PropanolAmyloseChiralpak ADMethanolPhenylcarbamatesPolysaccharidesAQbDChiral separationComputer-assisted method developmentDryLabOzanimodPolysaccharide-type chiral column

Identifiers

PMID39500751
PMCPMC11538454

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.