Evidence map›Paper›PMID 39499774›Full record

Observational studyClinical orthopaedics and related research2025

Is Socket Flexion Alignment Associated With Changes in Gait Parameters in Individuals With an Above-knee Amputation and a Hip Flexion Contracture?

Kevin Arribart, Valentin Peryoitte, Anton Kaniewski, Xavier Bonnet, Hélène Pillet

Abstract readComparative StudyObservational Study
In one paragraph

Observational study in Clinical orthopaedics and related research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kevin ArribartInstitut Robert Merle d'Aubigné, Valenton, France.ORCID 0000-0003-2694-6366
Valentin PeryoitteInstitut Robert Merle d'Aubigné, Valenton, France.
Anton KaniewskiInstitut Robert Merle d'Aubigné, Valenton, France.ORCID 0009-0007-0277-608
Xavier BonnetArts et Métiers Sciences et Technologies, Institut de Biomécanique Humaine Georges Charpak, Paris, France.ORCID 0000-0002-4903-4848
Hélène PilletArts et Métiers Sciences et Technologies, Institut de Biomécanique Humaine Georges Charpak, Paris, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA hip flexion contracture (HFC) results in an inability to extend the hip by reducing the ROM of the affected hip. The condition affects one in four patients with above-knee amputations on the amputation side. While HFC in other disorders is known to decrease hip ROM and increase pelvic tilt during gait, its impact on the gait of patients with above-knee amputations remains unexplored. Typically, prosthetists design the socket with a flexion angle matching the HFC, potentially leading to compensations during the posterior stance phase of the gait cycle. To our knowledge, little is known about how or whether these compensations relate to the socket's flexion alignment. QUESTIONS/PURPOSES: (1) Is the presence of HFC associated with modifications of spatiotemporal and kinematic parameters during gait in patients with an above-knee amputation? (2) Is there a correlation between the socket flexion angle and the spatiotemporal and kinematic parameters during gait in patients with an above-knee amputation with and without HFC?

methodsA comparative observational study was conducted between February 2022 and June 2023. Thirty-two participants with unilateral above-knee amputations who had undergone amputation at least 1 year prior and had a minimum of 1 month of experience with their current prostheses were eligible for consideration and included in the study. After the trial, 1 of 32 participants was excluded due to other impairments affecting gait, and 9% (3 of 32) were excluded because of pain or discomfort during data acquisition on their gait, leaving 88% (28 of 32) of participants included in the analysis. The median (IQR) age of participants in the HFC group (n = 13) was 50 years (26 to 56); 85% (11) were male and 15% (2) were female. The median (IQR) age of participants in the noHFC group (n = 15) was 41 years (32 to 56), and 100% were male. Time since amputation was similar between groups (HFC median 8 years [IQR 3 to 21], noHFC median 6 years [IQR 1 to 9], difference of medians 2; p = 0.31). Thirty-two percent (9 of 28) of patients were classified according to the Medicare Functional Classification Level system as K4 (exceeding basic ambulation skills) and 68% (19 of 28) were classified as K3 (ability to walk with variable cadence and traverse most environmental barriers). Clinical and prosthetic measurements were made, which comprised measurement of the HFC using a hand-held goniometer with the patient in the modified Thomas test position, the socket flexion alignment, and the difference (δ) between the HFC and socket flexion alignment. A gait analysis was performed with an optoelectronic system equipped with six infrared cameras and two force plates to analyze the time-distance and kinematic parameters of gait. To answer our first question, we quantitively compared the gait spatiotemporal and kinematic parameters between groups, and for the second question, we evaluated the correlations between the same parameters and prosthesis alignment for both groups.

resultsDuring gait, the HFC group exhibited reduced mean ± SD residual hip ROM in comparison with the noHFC group (35° ± 6° versus 44° ± 6°, mean difference -9° [95% CI -13° to -6°]; p < 0.001), increased pelvic tilt (11° ± 6° versus 7° ± 3°, mean difference 4° [95% CI 1° to 8°]; p = 0.02), increased pelvic rotation (12° ± 3° versus 9° ± 2°, mean difference 3° [95% CI 2° to 6°]; p < 0.001), and increased trunk rotation (15° ± 5° and 12° ± 2°, mean difference 3° [95% CI 0° to 6°]; p = 0.04). Greater δ correlated with decreased ROM in the contralateral hip (r = -0.71; p = 0.006), pelvis (r = -0.77; p = 0.002), and trunk (r = -0.58; p = 0.04) in the sagittal plane and with increased residual hip ROM (r = 0.62; p = 0.02). In terms of spatiotemporal gait parameters, in the HFC group, the δ correlated with an increase in contralateral step width (r = 0.58; p = 0.04) and a decrease in prosthetic step length (r = -0.65; p = 0.02).

conclusionOur findings further suggest that physiotherapists should consider the pelvic and trunk compensations associated with HFC in their rehabilitation because of potential long-term effects, such as low back pain or osteoarthritis. In addition, the correlation between the socket flexion angle and the parameters involved may support prosthetists in their choices of prosthetic settings. For now, we cannot consider these compensations as an impaired gait syndrome, and future studies are needed to evaluate their impact on patients' quality of life. LEVEL OF EVIDENCE: Level III, therapeutic study.

Indexed as

Amputation, SurgicalArtificial LimbsGaitHip ContractureHip JointAdultAmputeesBiomechanical PhenomenaFemaleHumansMaleMiddle AgedProsthesis DesignRange of Motion, Articular

Identifiers

PMID39499774
PMCPMC11828000

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.