ArticleRadiological physics and technology2025
Effectiveness of the air-gap method for reducing radiation dose in neonate CT examinations.
Article in Radiological physics and technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Contemporary strategies for dose optimization in pediatric congenital heart disease CT: size-specific acquisition and detector-level advances.Radiological physics and technology · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The air-gap method is a technique employed to control dose distribution and radiation scattering in medical imaging. By introducing a layer of air between the radiation source and the object, this method effectively reduces the impact of scattered radiation. The purpose of this study was to investigate the suitability of the air-gap method for radiation dose reduction in pediatric patients during computed tomography (CT) examinations. Only one type of neonate phantom is used with 64 detector-row CT scanner while helical scanning the chest. The distance between the CT table and the subject was 0 mm at the conventional method and 150 mm at the air-gap method. The values of the real-time skin dosimeter on the dorsal surface of the body, and on the left and right mammary glands and image noise are measured and compared for each method. Compared with the conventional method, it was possible to reduce the exposure dose and image noise by approximately 10% and 15%, respectively, using the air-gap method (p < 0.05). The air-gap method was useful for reducing the radiation dose during pediatric CT examinations compared with the conventional method.
Indexed as
Identifiers
39499357What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.