Evidence map›Paper›PMID 39497797›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2024

Evaluation of aneurysm flow divertor (stent) treatment using multi-angled 1000 fps High-Speed Angiography (HSA) and Optical Flow (OF).

E A Vanderbilt, R White, S V Setlur Nagesh, V K Chivukula, D R Bednarek, C N Ionita, S Rudin

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

E A VanderbiltUniversity of Buffalo, Buffalo, New York, USA; Canon Research Stroke and Vascular Center, Buffalo, New York, USA; Florida Institute of Technology, Melbourne, Florida.
R WhiteUniversity of Buffalo, Buffalo, New York, USA; Canon Research Stroke and Vascular Center, Buffalo, New York, USA; Florida Institute of Technology, Melbourne, Florida.
S V Setlur NageshUniversity of Buffalo, Buffalo, New York, USA; Canon Research Stroke and Vascular Center, Buffalo, New York, USA; Florida Institute of Technology, Melbourne, Florida.
V K ChivukulaUniversity of Buffalo, Buffalo, New York, USA; Canon Research Stroke and Vascular Center, Buffalo, New York, USA; Florida Institute of Technology, Melbourne, Florida.
D R BednarekUniversity of Buffalo, Buffalo, New York, USA; Canon Research Stroke and Vascular Center, Buffalo, New York, USA; Florida Institute of Technology, Melbourne, Florida.
C N IonitaUniversity of Buffalo, Buffalo, New York, USA; Canon Research Stroke and Vascular Center, Buffalo, New York, USA; Florida Institute of Technology, Melbourne, Florida.
S RudinUniversity of Buffalo, Buffalo, New York, USA; Canon Research Stroke and Vascular Center, Buffalo, New York, USA; Florida Institute of Technology, Melbourne, Florida.

Funding

High Speed Angiography at 1000 frames per secondR01EB030092 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2020 to 2023
$2.6M
NIBIB NIH HHS R01 EB030092
6 · The paper itself

Abstract

Understanding detailed hemodynamics is critical in the treatment of aneurysms and other vascular diseases; however, traditional digital subtraction angiography (DSA) does not provide detailed quantitative flow information. Instead, 1000 fps High-Speed Angiography (HSA) can be used for high-temporal visualization and evaluation of detailed blood flow patterns and velocity distributions. In the treatment of aneurysms, flow diverter expansion and positioning play a critical role in affecting the hemodynamics and optimal patient outcomes. Patient-specific aneurysm phantom imaging was done with a CdTe photon-counting detector (Aries, Varex). Treatment was done with a Pipeline Flex Embolization Device on a 3D-printed fusiform aneurysm phantom. The untreated aneurysm and two treatment stent expansions and positions were imaged, and velocity calculations were generated using Optical Flow (OF). Pre- and post-treatment images were then compared between different HSA image sequences and evaluated using OF with different stent positions. Differences in flow patterns due to changes in stent placement characteristics were identified and quantified with OF velocimetry. The velocity results within the aneurysm post-treatment showed significant flow reduction. Differences in stent placement result in substantial changes in velocities. The peak velocities found in the aneurysm dome show a reduction with the widened stent placement compared to the narrowed placement and both are reduced compared to the untreated aneurysm. The stent placements were compared quantitatively with the adjusted widened stent clearly better diverting the flow away from the aneurysm with decreased velocity in the aneurysm dome compared to both the narrowed stent placement and the untreated aneurysm. Providing this information in-clinic can help improve treatment and patient outcomes.

Indexed as

1000 fpsAneurysmFlow diverterHemodynamicsHigh Speed AngiographyInvitroMulti-angleOptical Flow

Identifiers

PMID39497797
PMCPMC11533909

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.