Evidence map›Paper›PMID 39496864›Full record

ArticleJapanese journal of radiology2025

Utility of under-sampled scans with iterative reconstruction and high-frequency preserving transform for high spatial resolution magnetic resonance cholangiopancreatography.

Shota Kondo, Yuko Nakamura, Toru Higaki, Takashi Nishihara, Masahiro Takizawa, Toru Shirai, Motoshi Fujimori, Yoshitaka Bito, Keigo Narita, Dara Fonseca and 4 more

Abstract read
In one paragraph

Article in Japanese journal of radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Shota KondoDiagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-Ku, Hiroshima City, Hiroshima, 734-8551, Japan.
Yuko NakamuraDiagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-Ku, Hiroshima City, Hiroshima, 734-8551, Japan. yukon@hiroshima-u.ac.jp.ORCID http://orcid.org/0000-0003-3128-4731
Toru HigakiDiagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-Ku, Hiroshima City, Hiroshima, 734-8551, Japan.
Takashi NishiharaFUJIFILM Corporation, 2-1, Shintoyofuta, Kashiwa City, Chiba, 277-0804, Japan.
Masahiro TakizawaFUJIFILM Corporation, 2-1, Shintoyofuta, Kashiwa City, Chiba, 277-0804, Japan.
Toru ShiraiFUJIFILM Corporation, 2-1, Shintoyofuta, Kashiwa City, Chiba, 277-0804, Japan.
Motoshi FujimoriFUJIFILM Corporation, 2-1, Shintoyofuta, Kashiwa City, Chiba, 277-0804, Japan.
Yoshitaka BitoFUJIFILM Corporation, 2-1, Shintoyofuta, Kashiwa City, Chiba, 277-0804, Japan.
Keigo NaritaDiagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-Ku, Hiroshima City, Hiroshima, 734-8551, Japan.
Dara FonsecaDiagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-Ku, Hiroshima City, Hiroshima, 734-8551, Japan.
Shogo MaedaDiagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-Ku, Hiroshima City, Hiroshima, 734-8551, Japan.
Ikuo KawashitaDiagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-Ku, Hiroshima City, Hiroshima, 734-8551, Japan.
Yukiko HondaDiagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-Ku, Hiroshima City, Hiroshima, 734-8551, Japan.
Kazuo AwaiDiagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-Ku, Hiroshima City, Hiroshima, 734-8551, Japan.

Funding

Fujifilm Corporation 0G20KA7113
6 · The paper itself

Abstract

purposeUnder-sampled scans with iterative reconstruction and high-frequency preserving transform (Us-IRHF) can increase the acquisition speed without degrading the image quality by recovering image information from under-sampled data. We investigate the clinical applicability of high spatial resolution magnetic resonance cholangiopancreatography (MRCP) images without extending the scanning time using Us-IRHF.

methodsA slit phantom was scanned with conventional- (without Us-IRHF), Us-IR- (without HF), and Us-IRHF scanning. The matrix size was 320 × 320 for Us-IR- and Us-IRHF- and 288 × 208 for conventional scanning. Modulation transfer function (MTF) focused on the 1.0 lp/cm gauge for each scanning was calculated. For clinical study we acquired respiratory-triggered 3D MRCP scans with and without Us-IRHF (U

resultsPhantom study showed that compared to the conventional- and Us-IR (without HF) images, the MTF for the Us-IRHF image revealed the highest response. For clinical study, the mean acquisition time was 161 s for U

conclusionUs-IRHF improved the image quality of high spatial resolution MRCP without extending the scanning time.

Indexed as

Cholangiopancreatography, Magnetic ResonanceImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedAdultAgedAged, 80 and overFemaleHumansImaging, Three-DimensionalMaleMiddle AgedPhantoms, ImagingHigh-frequency preserving transformIterative reconstructionMagnetic resonance cholangiopancreatographySpatial resolutionUnder-sampled scans

Identifiers

PMID39496864
PMCPMC11868363

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.