ArticleThe international journal of cardiovascular imaging2026
Diagnostic performance of high and ultra-high-resolution photon counting CT for detection of coronary artery disease in patients evaluated for transcatheter aortic valve implantation.
Article in The international journal of cardiovascular imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- A scoping review of photon-counting detector computed tomography in cardiovascular imaging.Diagnostic and interventional radiology (Ankara, Turkey) · 2026Article
- Clinical benefits and current challenges of photon-counting detector CT in vascular imaging.Radiology advances · 2026Review
- Diagnostic Performance of Photon-Counting CT Angiography in Vascular Stenosis Assessment: A Systematic Review and Meta-Analysis.Diagnostics (Basel, Switzerland) · 2026Review
- Photon-Counting CT in Cardiovascular Imaging: Clinical Applications.Korean journal of radiology · 2026Review
- Low-tube-potential ultra-high-resolution coronary CTA with photon-counting detector CT for stent evaluation: a comparative feasibility study.Japanese journal of radiology · 2025Article
- Dysglycaemia is associated with the pattern of valvular calcification in micro-computed tomography analysis: an observational study in patients with severe aortic stenosis.Cardiovascular diabetology · 2025Observational
- Review
- Value of Ultrahigh-Resolution Photon-Counting Detector Computed Tomography in Cardiac Imaging.Echocardiography (Mount Kisco, N.Y.) · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We assessed the diagnostic performance of both ultra-high-resolution (UHR) and high-resolution (HR) modes of photon-counting detector (PCD)-CT within the confines of standard pre-TAVI CT scans, as well as the performance of UHR mode adjusted specifically for coronary imaging, using quantitative coronary angiography (QCA) as the reference. We included 60 patients undergoing pre-TAVI planning CT scans. Patients were divided into 3 groups: 20 scanned in HR mode, 20 in UHR mode, and 20 in adjusted UHR mode, on a dual-source PCD-CT. The adjusted UHR mode employed a lower tube voltage (90 kV vs. 120 kV) and a higher image quality level (65 vs. 34) to enhance coronary artery visualization. Patients underwent invasive coronary angiography as part of clinical routine. CCTA and QCA were reviewed to assess CAD presence defined as stenosis ≥ 50% in proximal and middle coronary segments. We included 60 patients (mean age 79 ± 7 years; 39(65%) men). Mean heart rate during scanning was 72 ± 13 bpm. Median coronary calcium score was 973 [379-2007]. QCA identified significant CAD in 24 patients (40%): 9 patients scanned with HR mode, 10 patients with the UHR mode, and 5 patients with the UHR adjusted mode. Per-patient area under the curves were 0.57 for HR, 0.80 for UHR, and 0.80 for adjusted UHR, with no significant differences between the scan modes, and per-vessel the area under the curves were 0.73 for HR, 0.69 for UHR, and 0.87 for adjusted UHR, with significant differences between UHR and adjusted UHR (p = 0.04). UHR and adjusted UHR modes of dual source PCD-CT show potential for improved sensitivity and negative predictive value for detecting CAD in patients undergoing pre-TAVI scans, however, no statistically significant difference from HR mode was observed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials