Self-Reporting Multiple Microscopic Stresses Through Tunable Microcapsule Arrays.

Minghan Hu, Zhongqi Ma, Minsoo Kim, Donghoon Kim, Suiying Ye, Salvador Pané, Yinyin Bao, Robert W Style, Lucio Isa

Abstract read
In one paragraph

Article in Advanced materials (Deerfield Beach, Fla.), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Minghan HuLaboratory for Soft Materials and Interfaces, Department of Materials, ETH Zürich, Vladimir-Prelog-Weg 5, Zürich, 8093, Switzerland.ORCID https://orcid.org/0000-0002-9001-6780
Zhongqi MaLaboratory for Soft Materials and Interfaces, Department of Materials, ETH Zürich, Vladimir-Prelog-Weg 5, Zürich, 8093, Switzerland.ORCID https://orcid.org/0009-0002-1910-980X
Minsoo KimMulti-Scale Robotics Lab, Institute of Robotics and Intelligent Systems, ETH Zurich, Tannenstrasse 3, Zurich, 8092, Switzerland.
Donghoon KimMulti-Scale Robotics Lab, Institute of Robotics and Intelligent Systems, ETH Zurich, Tannenstrasse 3, Zurich, 8092, Switzerland.
Suiying YeInstitute of Pharmaceutical Sciences, Department of Chemistry and Applied Biosciences, ETH Zurich, Vladimir-Prelog-Weg 3, Zurich, 8093, Switzerland.ORCID https://orcid.org/0000-0003-1607-0807
Salvador PanéMulti-Scale Robotics Lab, Institute of Robotics and Intelligent Systems, ETH Zurich, Tannenstrasse 3, Zurich, 8092, Switzerland.ORCID https://orcid.org/0000-0003-0147-8287
Yinyin BaoInstitute of Pharmaceutical Sciences, Department of Chemistry and Applied Biosciences, ETH Zurich, Vladimir-Prelog-Weg 3, Zurich, 8093, Switzerland.ORCID https://orcid.org/0000-0001-5264-1211
Robert W StyleLaboratory for Soft Materials and Interfaces, Department of Materials, ETH Zürich, Vladimir-Prelog-Weg 5, Zürich, 8093, Switzerland.ORCID https://orcid.org/0000-0001-5305-7658
Lucio IsaLaboratory for Soft Materials and Interfaces, Department of Materials, ETH Zürich, Vladimir-Prelog-Weg 5, Zürich, 8093, Switzerland.ORCID https://orcid.org/0000-0001-6731-9620

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Self-reporting materials have emerged as a promising tool for real-time monitoring of stress and damage in structural materials. When critical stress is applied to these materials, an optical response is triggered - for example by dye release, or molecular cleavage. A key challenge is to extend these systems to respond to multiple different stress levels. To achieve this, a novel microcapsule-based assembly strategy is presented. Microfluidic synthesis is used to create microcapsules that release dye at a precise level of applied force. Subsequently, capillary assembly is used to combine microcapsules with different stress-responsiveness and different fluorescent dyes into chains, which are uniformly patterned into regular arrays, and embed these into the self-reporting materials. Through indentation experiments, it is shown that these materials can distinguish and record spatially resolved local stresses based on the fluorescence emitted upon microcapsule rupture. Crucially, the technique's accuracy is significantly improved when microcapsules are spatially organized within the material. This versatile technique can be applied to a range of different materials, via the use of thin coatings containing the regularly patterned microcapsule chains.

Indexed as

capillary assemblymicrofluidicsself‐reporting microcapsulesstress mapping

Identifiers

PMID39494966
PMCPMC11758236

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.