Evidence map›Paper›PMID 39493174›Full record

ArticleCureus2024

Evaluation of Leg Length Difference on Perioperative Radiographs of Total Hip Arthroplasty Considering Lower Limb Malposition.

Yasuhiko Kokubu, Shinya Kawahara, Yusuke Ayabe, Goro Motomura, Satoshi Hamai, Toshihiko Hara, Yasuharu Nakashima

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yasuhiko KokubuDepartment of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, JPN.
Shinya KawaharaDepartment of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, JPN.
Yusuke AyabeDepartment of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, JPN.
Goro MotomuraDepartment of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, JPN.
Satoshi HamaiDepartment of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, JPN.
Toshihiko HaraDepartment of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, JPN.
Yasuharu NakashimaDepartment of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, JPN.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDuring total hip arthroplasty (THA) in lateral decubitus, perioperative radiography allows the surgeon a simple evaluation of the leg length difference (LLD) by measuring the proximal femoral length. However, the effect of femoral malpositioning on proximal femoral length measurements during the evaluation of perioperative radiographs is not adequately understood. We aimed to (1) investigate the effects of malposition on proximal femoral length using three-dimensional computer simulations and (2) verify whether a simple correction formula can improve the accuracy of LLD evaluation on perioperative radiographs.

methodsWe analyzed 86 patients who underwent THA. Digitally reconstructed radiography (DRR) images were reconstructed in various limb positions (femoral abduction, adduction, and flexion), and proximal femoral length measurements in those malpositions were simulated. Additional morphological measurements of the femoral neck torsion angle in the sagittal plane were performed to elucidate the simulation findings. The malposition angle of abduction-adduction was evaluated with actual perioperative radiographs, and trigonometric correction was attempted.

resultsThe leg length measurement decreased as the femoral DRR image shifted from neutral to abduction and adduction, demonstrating approximately 1 mm per 10° of abduction or adduction. The leg length measurement increased as the femoral image shifted from neutral to 10° and 20° of flexion, demonstrating approximately 3 mm per 10° of flexion. With a peak at 20° of flexion, the proximal femoral length measurement decreased in the DRR images at 30°, 40°, 50° and 60° of flexion. The femoral neck torsion angle was 21.1 ± 5.6° on the operative side. The effect of coronal malposition on leg length discrepancy was so small that the difference following trigonometric correction was not statistically significant (p=0.108).

conclusionIn the present simulation, coronal malposition had a small effect on LLD evaluation. As the femoral neck has a torsion of approximately 20°, the proximal femoral length is projected the longest when the femur is flexed 20°. With careful positioning of the limb in the coronal plane, the use of a correction formula for LLD evaluation would not be necessary. Surgeons should ensure that both lower limbs are in the same position in the sagittal plane during THA in lateral decubitus.

Indexed as

digitally reconstructed radiographyhipleg lengthmalpositioningtotal hip arthroplasty

Identifiers

PMID39493174
PMCPMC11531339

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.