Evidence map›Paper›PMID 39493058›Full record

ArticleCureus2024

Quantifying the Positional Deviation Between the True Flexion-Extension and Epicondylar Axes of the Elbow: A 3D Computational Study.

Jonathan Zhi-Wei Gan, Pivatidevi Pareatumbee, Andy Yew, Zehao Tan, Don Thong Siang Koh, Tet-Sen Howe, Suang-Bee Joyce Koh, Bernard Morrey, Yeong Huei Ng

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jonathan Zhi-Wei GanAcademic Clinical Program-Musculoskeletal Sciences, Singapore General Hospital, Singapore, SGP.
Pivatidevi PareatumbeeAcademic Clinical Program-Musculoskeletal Sciences, Singapore General Hospital, Singapore, SGP.
Andy YewAcademic Clinical Program-Musculoskeletal Sciences, Singapore General Hospital, Singapore, SGP.
Zehao TanVascular and Interventional Radiology, Singapore General Hospital, Singapore, SGP.
Don Thong Siang KohAcademic Clinical Program-Musculoskeletal Sciences, Singapore General Hospital, Singapore, SGP.
Tet-Sen HoweAcademic Clinical Program-Musculoskeletal Sciences, Singapore General Hospital, Singapore, SGP.
Suang-Bee Joyce KohAcademic Clinical Program-Musculoskeletal Sciences, Singapore General Hospital, Singapore, SGP.
Bernard MorreyOrthopaedic Surgery, Mayo Clinic, Rochester, USA.
Yeong Huei NgAcademic Clinical Program-Musculoskeletal Sciences, Singapore General Hospital, Singapore, SGP.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and objective The epicondyles are commonly used surgical reference landmarks for elbow arthroplasty and external fixator application. This study aimed to investigate whether the epicondylar axis differed from the elbow's true flexion-extension (F-E) axis in terms of both rotational difference and translational offset. Methods Three-dimensional (3D) models of 15 cadaver elbows were created. The epicondylar, true F-E, and distal humeral axes were defined using the medial and lateral epicondyles and the normal vector through the trochlear groove's center respectively. Rotational difference along internal-external, varus-valgus, and flexion-extension rotation plane and translational offset in the anterior-posterior (A-P), medial-lateral (M-L), and inferior-superior (I-F) direction with reference to the distal humerus's long axis were measured. Results Minimal rotational differences of 1.9 ± 4.5, 2.1 ± 3.4, and 0.5 ± 2.7 degrees for flexion-extension, varus-valgus, and internal-external rotation were obtained respectively. Considerable translational offsets greater than 10 mm were found for the absolute medial and lateral translational offset with a statistically significant difference recorded in the M-L direction. Conclusions Small rotational differences exist between the epicondylar and true F-E axes. Significant differences are observed in the translational offset in the M-L direction and should be considered during implant alignment in order to reduce malalignment and prevent failure.

Indexed as

3d modellingelbow flexion axishumerusimplant alignmenttotal elbow replacement

Identifiers

PMID39493058
PMCPMC11531660

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.