ArticleWorld journal of cardiology2024
Percutaneous decannulation of extracorporeal membrane oxygenation using MANTA device: A real-world single-center experience.
Article in World journal of cardiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Percutaneous Closure of a Large-Bore Carotid Arteriotomy Using a Collagen-Based Vascular Plug.Life (Basel, Switzerland) · 2026Article
- On MANTA vascular closure devices following veno arterial extracorporeal membrane oxygenation: Effectiveness and complications.World journal of cardiology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe MANTA vascular closure device (VCD) represents a novel approach to achieving hemostasis after large-bore femoral access procedures. Numerous clinical studies have evaluated the efficacy of the MANTA device across a range of patient populations undergoing different procedures. However, there is still a paucity of data available concerning the use of MANTA devices in aiding the decannulation of venoarterial extracorporeal membrane oxygenation (VA-ECMO).
aimTo present our single-center experience of utilizing the MANTA VCD in patients undergoing this procedure.
methodsThis single-center study included all patients undergoing percutaneous decannulation of femoral VA-ECMO using the MANTA plug-based VCD between January 2021 and October 2023 at University Hospitals Cleveland Medical Center. Inclusion criteria were adult patients who required prolonged (> 24 hours) hemodynamic support with VA-ECMO. Outcomes included all-cause mortality, hemostasis, bleeding, limb ischemia, and site infection.
resultsThis is a retrospective cohort study of 19 patients with a mean age of 56.8 years. Twelve of them were males with a mean body mass index of 29. The most common extracorporeal membrane oxygenation indication was acute coronary syndrome complicated by cardiogenic shock at 36.8%. The mean length of intensive care unit stay for these patients was 18.8 ± 8.42 days. Seventeen out of 19 patients survived to discharge. The MANTA device was successfully deployed in 19 patients, with 10 procedures conducted at the bedside and 9 in an operating room setting. Complete hemostasis was achieved within 5 minutes of MANTA deployment in 17 out of 19 patients. In 2 patients manual compression after Manta deployment was required to achieve adequate hemostasis. Additionally, acute lower extremity ischemia was noted in two patients, necessitating endovascular interventions. No infections were reported at the site of MANTA deployment.
conclusionOverall, based on our experience and that of other centers, the MANTA VCD has proven to be a simple, safe, and effective percutaneous technique for facilitating in the OR, but most of all it opens the opportunity for bedside VA-ECMO decannulation. Post-decannulation ischemic complications are higher in this series of sick patients when compared with elective procedures like transcatheter aortic valve replacement and endovascular aneurysm repair. Additionally, operators should be mindful of the incidence of ischemic complications. Distal Doppler pulse signals should always be checked, to indicate bailout options when this occurs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.