ArticleAnalytical sciences : the international journal of the Japan Society for Analytical Chemistry2025

pH monitoring in high ionic concentration environments: performance study of graphene-based sensors.

Xin Qi, Wei Jin, Cao Tang, Xue Xiao, Rui Li, Yanqing Ma, Lei Ma

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xin QiTianjin International Center for Nanoparticles and Nanosystems, Tianjin University, 92 Weijin Road, Nankai District, Tianjin, 300072, People's Republic of China.
Wei JinTianjin International Center for Nanoparticles and Nanosystems, Tianjin University, 92 Weijin Road, Nankai District, Tianjin, 300072, People's Republic of China.
Cao TangTianjin International Center for Nanoparticles and Nanosystems, Tianjin University, 92 Weijin Road, Nankai District, Tianjin, 300072, People's Republic of China.
Xue XiaoTianjin International Center for Nanoparticles and Nanosystems, Tianjin University, 92 Weijin Road, Nankai District, Tianjin, 300072, People's Republic of China.
Rui LiTianjin International Center for Nanoparticles and Nanosystems, Tianjin University, 92 Weijin Road, Nankai District, Tianjin, 300072, People's Republic of China.
Yanqing MaTianjin International Center for Nanoparticles and Nanosystems, Tianjin University, 92 Weijin Road, Nankai District, Tianjin, 300072, People's Republic of China. mayanqing@tju.edu.cn.
Lei MaTianjin International Center for Nanoparticles and Nanosystems, Tianjin University, 92 Weijin Road, Nankai District, Tianjin, 300072, People's Republic of China. lei.ma@tju.edu.cn.ORCID http://orcid.org/0000-0002-2446-4833

Funding

Key Technologies Research and Development Program 2022YFC3006303
6 · The paper itself

Abstract

Graphene-based pH sensors, acclaimed for their exceptional sensitivity to environmental variations, have garnered significant interest in scientific research. However, the sensor performance in high ionic concentration environments is limited, due to the Debye length ion screening effect. In this study, an innovative graphene channel pH sensing device was developed and modified by cross-linked poly(methyl methacrylate) (PMMA). Furthermore, even in high ionic concentrations, the pH value can be precisely measured by this sensor. The sensor has remarkable sensitivity, and high response rate of - 70.49 mV/pH within the pH range from 7 to 10. Notably, the sensors retain uniform response direction and sensitivity under different ionic concentrations environmental and maintain consistent reversibility and stability. This advancement in sensor technology paves the way for broader applications in complex ionic environments.

Indexed as

CVD grapheneHigh ionic concentrationpH sensorSolution gate field-effect transistor