ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2025
Robotic assistance for upper cervical instrumentation: report on accuracy and safety.
Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Robotically equipped 3D hybrid operating room in spine and trauma surgery - updated experience in 359 patients and 2080 screws.Journal of robotic surgery · 2026Article
- Orthopedic Biomaterials in the Clinical Reconstruction of Osteoporotic Atlantoaxial Injuries: A Review.Bioengineering (Basel, Switzerland) · 2026Review
- 5G-Enabled remote Robotic-Assisted percutaneous pedicle screw fixation in single thoracolumbar fractures: initial clinical feasibility and safety evaluation.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Article
- Global research trends in robot-assisted spinal surgery: a visualized bibliometric analysis.Journal of robotic surgery · 2025Review
- Letter to the editor Regarding 'Causal relationship between basal metabolic rate and intervertebral disc degeneration: a Mendelian randomization study' by Liu Z, et al. (Eur Spine J. 2024 Jun 24. Doi: 10.1007/s00586-024-08367-7).European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
purposeThis study aims to evaluate the accuracy and safety of C1 lateral mass and upper cervical pedicle screw placement assisted by the TiRobot II system.
methodsTen patients who underwent cervical spine surgery assisted by the TiRobot II system were included. Screw accuracy was assessed using the Gertzbein-Robbins scale and by comparing the final screw positions with pre-planned trajectories. Deviations in screw tip, tail, and angle were recorded. Clinical data, including symptoms, surgical outcomes, and postoperative follow-up, were collected. Neurological improvement was evaluated using pre- and post-operative mJOA scores, with recovery rates calculated by Hirabayashi's method to assess outcomes 3 months after surgery.
resultsA total of 30 screws were placed in 10 patients. All screws (30/30) were within the clinically acceptable range, with 93.33% (28 screws) classified as Grade A and 6.67% (2 screws) as Grade B. In the sagittal plane, the average tip deviation was 1.82 ± 0.79 mm, tail deviation 1.64 ± 0.60 mm, and angular deviation 1.92 ± 1.39°. In the axial plane, tip deviation was 1.96 ± 0.87 mm, tail deviation 1.92 ± 0.65 mm, and angular deviation 2.01 ± 1.07°. The average surgery time was 318.80 ± 66.07 min, with a mean EBL of 205.00 ± 55.03 mL. Postoperative mJOA scores significantly improved from 8.10 ± 1.97 to 12.60 ± 1.78 (p < 0.05), with a 52 ± 14% recovery rate. All patients showed significant symptom improvement.
conclusionThe TiRobot II system demonstrates the capability to precisely execute pre-planned trajectories and improves the accuracy and safety of C1 lateral mass and upper cervical screw placement.