Evidence map›Paper›PMID 39483990›Full record

ArticleFrontiers in medical technology2024

Motion artifact variability in biomagnetic wearable devices.

Negin Ghahremani Arekhloo, Huxi Wang, Hossein Parvizi, Asfand Tanwear, Siming Zuo, Michael McKinlay, Carlos Garcia Nuñez, Kianoush Nazarpour, Hadi Heidari

Abstract read
In one paragraph

Article in Frontiers in medical technology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Medium density EMG armband for gesture recognition.Frontiers in neurorobotics · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Negin Ghahremani ArekhlooNeuranics Limited, Glasgow, United Kingdom.
Huxi WangNeuranics Limited, Glasgow, United Kingdom.
Hossein ParviziMicroelectronics Lab, James Watt School of Engineering, University of Glasgow, Glasgow, United Kingdom.
Asfand TanwearNeuranics Limited, Glasgow, United Kingdom.
Siming ZuoNeuranics Limited, Glasgow, United Kingdom.
Michael McKinlayMicroelectronics Lab, James Watt School of Engineering, University of Glasgow, Glasgow, United Kingdom.
Carlos Garcia NuñezMicroelectronics Lab, James Watt School of Engineering, University of Glasgow, Glasgow, United Kingdom.
Kianoush NazarpourNeuranics Limited, Glasgow, United Kingdom.
Hadi HeidariNeuranics Limited, Glasgow, United Kingdom.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Motion artifacts can be a significant noise source in biomagnetic measurements when magnetic sensors are not separated from the signal source. In ambient environments, motion artifacts can be up to ten times stronger than the desired signals, varying with environmental conditions. This study evaluates the variability of these artifacts and the effectiveness of a gradiometer in reducing them in such settings. To achieve these objectives, we first measured the single channel output in varying magnetic field conditions to observe the effect of homogeneous and gradient background fields. Our analysis revealed that the variability in motion artifact within an ambient environment is primarily influenced by the gradient magnetic field rather than the homogeneous one. Subsequently, we configured a gradiometer in parallel and vertical alignment with the direction of vibration (X-axis). Our findings indicated that in a gradient background magnetic field ranging from 1 nT/mm to 10 nT/mm, the single-channel sensor output exhibited a change of 164.97 pT per mm unit increase, while the gradiometer output showed a change of only 0.75 pT/mm within the same range. Upon repositioning the gradiometer vertically (Y direction), perpendicular to the direction of vibration, the single-channel output slope increased to 196.85 pT, whereas the gradiometer output only increased by 1.06 pT/mm for the same range. Our findings highlight the influence of ambient environments on motion artifacts and demonstrate the potential of gradiometers to mitigate these effects. In the future, we plan to record biomagnetic signals both inside and outside the shielded room to compare the efficacy of different gradiometer designs under varying environmental conditions.

Indexed as

biomagnetic measurementsgradient background fieldhomogeneous background fieldmotion artifactswearable sensors

Identifiers

PMID39483990
PMCPMC11524837

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.