Evidence map›Paper›PMID 39480069›Full record

ArticleJournal of clinical microbiology2024

Performance of the LifeScale automated rapid phenotypic antimicrobial susceptibility testing on Gram-negative rods directly from positive blood cultures.

James W Snyder, Nadia Chaudhry, Wesley Hoffmann

Erratum issuedAbstract readEvaluation Study
In one paragraph

Article in Journal of clinical microbiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Rapid commercial CTX-M diagnostics: Performance, limitations and clinical impact.European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology · 2026
    Review
  5. Review
  6. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors.

James W SnyderDepartment of Pathology and Laboratory Medicine, Section of Clinical Microbiology and Infectious Diseases Molecular Diagnostics, University of Louisville, Louisville, Kentucky, USA.ORCID 0000-0003-4824-762X
Nadia ChaudhryDepartment of Pathology and Laboratory Medicine, Section of Clinical Microbiology and Infectious Diseases Molecular Diagnostics, University of Louisville, Louisville, Kentucky, USA.
Wesley HoffmannUofL Healthcare System, Louisville, Kentucky, USA.ORCID 0000-0002-1180-021X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Rapid antimicrobial susceptibility testing (rAST) performed directly from blood cultures is essential to influencing the selection of appropriate antibiotics, preferably targeted therapy, for the treatment of bloodstream infections. Affinity Biosensors has developed the LifeScale, a phenotypic rAST system based on microfluidic sensors with a mechanical resonator that measures the mass of individual microbes. The combination of replication, biomass, and population profiling of individual microbes is analyzed to produce rAST results. The performance of the LifeScale was evaluated and compared to our current standard of care (SOC) antimicrobial susceptibility testing (AST) system under clinical conditions. The results indicated that the LifeScale is easy to use and provides rapid, reliable, and accurate AST results in less than 5 h directly from from positive blood cultures containing Gram-negative organisms listed in the current database. For all organism-antibiotic combinations involving polymicrobial cultures, LifeScale showed a resistant result when either mixed isolate was resistant. If these results prove to be robust on further testing, this may justify the reporting of rapid LifeScale results without the need for additional confirmatory testing. IMPORTANCE: This is the first clinical-based study of a unique technology using microfluidic sensors to generate rapid antimicrobial susceptibility test results directly from blood cultures containing Gram-negative rods. The issue of polymicrobial cultures was also addressed in this study, which, to our knowledge, has not been addressed in publications of other rapid phenotypic AST systems. Overall, LifeScale results compared favorably with the SOC in terms of overall agreement, especially categorical agreement.

Indexed as

Anti-Bacterial AgentsBlood CultureGram-Negative BacteriaMicrobial Sensitivity TestsAutomation, LaboratoryBacteremiaBiosensing TechniquesGram-Negative Bacterial InfectionsHumansTime FactorsAnti-Bacterial Agentsantimicrobial stewarshipantimicrobial susceptibility testingblood culutresGram-negative bacteriaGram stainMALDI-TOFmicrofluidicsMicroScanpolymicrobialVerigene

Identifiers

PMID39480069
PMCPMC11633210

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.