ReviewJournal of experimental orthopaedics2024
Kinematic versus mechanical alignment: A systematic review of systematic reviews and meta-analyses of randomised controlled trials.
Review in Journal of experimental orthopaedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Improved alignment accuracy but similar early clinical outcomes with NAVIO imageless robotic-assisted vs. conventional total knee arthroplasty: a meta-analysis.Journal of orthopaedic surgery and research · 2025Pooled it
- Six-degree-of-freedom knee motion during treadmill walking in mechanically and kinematically aligned TKA.Scientific reports · 2026Trial
- Full-flexion gap balancing-driven personalized preoperative planning for TKA: biomechanical evidence of improved load symmetry in an in vitro model.Arthroplasty (London, England) · 2026Article
- Restricted kinematic alignment in total knee arthroplasty achieves equivalent or superior functional outcomes to mechanical alignment without compromising implant survivorship: A systematic review.Journal of orthopaedics · 2026Review
- Robotic-assisted total knee replacement: a narrative review of evolution, clinical impact, and future prospects in AI-driven precision surgery.Annals of medicine and surgery (2012) · 2026Review
- Biomechanical analysis of surgical alignment and design in total knee arthroplasty.Archives of orthopaedic and trauma surgery · 2026Article
- Does surgeon handedness affect the outcomes after primary total knee arthroplasty? A retrospective cohort study.World journal of orthopedics · 2026Article
- Simultaneous bilateral total knee arthroplasty with and without patellar resurfacing using a zirconium ceramic femoral component demonstrated equivalent short-term outcomes: A prospective randomised clinical trial.Journal of experimental orthopaedics · 2025Article
- Posterior tibial slope is independent of coronal plane knee alignment and needs to be assessed to determine knee phenotype.Journal of orthopaedics · 2025Article
- The HKA axis varies significantly with knee motion: A robot-assisted intraoperative evaluation during total knee arthroplasty supports the use of dynamic, not static, alignment classifications.Journal of experimental orthopaedics · 2025Article
- Comparative outcomes of kinematically aligned TKA with medial stabilized design vs. mechanically aligned TKA with bi-cruciate stabilized design: A propensity score-matched analysis.Journal of orthopaedics · 2025Article
- Sarcopenia and osteo-sarcopenia: Nonnegotiable patient-related aspects to consider when comparing kinematic and mechanical alignment strategies for total knee arthroplasty.Journal of experimental orthopaedics · 2025Article
- Kinematic versus mechanical alignment: A systematic review of systematic reviews and meta-analyses of randomised controlled trials.Journal of experimental orthopaedics · 2024Review
Corrections and comments
- Commented on by
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: The purpose of this study was to review the currently available systematic reviews and meta-analyses comparing kinematic alignment (KA) and mechanical alignment (MA). Methods: A literature search was performed to obtain all systematic review and meta-analyses comparing KA to MA that included one or more randomised controlled trials. A total of 18 studies were obtained, three of which were systematic reviews without meta-analysis. Studies were evaluated based on their meta-analysis methodology, appropriate inclusion criteria, the use of correct definitions of each alignment technique, and risk of bias. Results: These 18 studies included between 3 and 14 RCTs in each study. From the perspective of study design, the majority of papers had low risk of bias. In contrast, most of these reviews had technical issues pertaining to study inclusion in their meta-analyses that would potentially compromise their conclusions. These included mixing time points in the analysis, duplicate inclusion of patients in a meta-analysis, inclusion of studies with incorrect definitions of KA, inclusion of studies performed with restricted kinematic alignment with the KA group, and inappropriate combination of studies with bilateral total knee arthroplasty (TKA) with studies with unilateral TKA. Conclusions: The current literature is inadequate to determine if there is any advantage to KA compared to MA in TKA. Claims made in systematic reviews and meta-analyses on the subject must be carefully scrutinised based not only on risk of bias but also on the included study populations, the surgical methodology of each underlying study, and the authors' understanding of the definitions of each alignment technique. Level of Evidence: Level 1 based on this study being a systematic review with the inclusion of only systematic reviews and meta-analyses of randomised controlled trials.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.