ArticleJMIR dermatology2022
Assessing the Generalizability of Deep Learning Models Trained on Standardized and Nonstandardized Images and Their Performance Against Teledermatologists: Retrospective Comparative Study.
Article in JMIR dermatology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Evaluating the Performance of Artificial Intelligence in Accurately Detecting Skin Cancer: An Umbrella Review of Systematic Reviews and Meta-analyses.American journal of clinical dermatology · 2026Pooled it
- Benchmark-Driven Clinical Decision Framework for Multi-Class Middle Ear Disease Diagnosis: Superiority of Swin Transformer in Accuracy and Stability.Diagnostics (Basel, Switzerland) · 2026Article
- Multi-task AI models in dermatology: Overcoming critical clinical translation challenges for enhanced skin lesion diagnosis.Journal of the European Academy of Dermatology and Venereology : JEADV · 2025Article
- Deep learning-based malaria parasite detection: convolutional neural networks model for accurate species identification of Plasmodium falciparum and Plasmodium vivax.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundConvolutional neural networks (CNNs) are a type of artificial intelligence that shows promise as a diagnostic aid for skin cancer. However, the majority are trained using retrospective image data sets with varying image capture standardization.
objectiveThe aim of our study was to use CNN models with the same architecture-trained on image sets acquired with either the same image capture device and technique (standardized) or with varied devices and capture techniques (nonstandardized)-and test variability in performance when classifying skin cancer images in different populations.
methodsIn all, 3 CNNs with the same architecture were trained. CNN nonstandardized (CNN-NS) was trained on 25,331 images taken from the International Skin Imaging Collaboration (ISIC) using different image capture devices. CNN standardized (CNN-S) was trained on 177,475 MoleMap images taken with the same capture device, and CNN standardized number 2 (CNN-S2) was trained on a subset of 25,331 standardized MoleMap images (matched for number and classes of training images to CNN-NS). These 3 models were then tested on 3 external test sets: 569 Danish images, the publicly available ISIC 2020 data set consisting of 33,126 images, and The University of Queensland (UQ) data set of 422 images. Primary outcome measures were sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC). Teledermatology assessments available for the Danish data set were used to determine model performance compared to teledermatologists.
resultsWhen tested on the 569 Danish images, CNN-S achieved an AUROC of 0.861 (95% CI 0.830-0.889) and CNN-S2 achieved an AUROC of 0.831 (95% CI 0.798-0.861; standardized models), with both outperforming CNN-NS (nonstandardized model; P=.001 and P=.009, respectively), which achieved an AUROC of 0.759 (95% CI 0.722-0.794). When tested on 2 additional data sets (ISIC 2020 and UQ), CNN-S (P<.001 and P<.001, respectively) and CNN-S2 (P=.08 and P=.35, respectively) still outperformed CNN-NS. When the CNNs were matched to the mean sensitivity and specificity of the teledermatologists on the Danish data set, the models' resultant sensitivities and specificities were surpassed by the teledermatologists. However, when compared to CNN-S, the differences were not statistically significant (sensitivity: P=.10; specificity: P=.053). Performance across all CNN models as well as teledermatologists was influenced by image quality.
conclusionsCNNs trained on standardized images had improved performance and, therefore, greater generalizability in skin cancer classification when applied to unseen data sets. This finding is an important consideration for future algorithm development, regulation, and approval.