Evidence map›Paper›PMID 39473928›Full record

ArticleFrontiers in bioengineering and biotechnology2024

Enhancing the precision of continuum robots in orthopedic surgery based on mechanical principles.

Tongtao Pang, Jinkui Liang, Zechen Lin, Xubin Zhang, Finxin Du

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Tongtao PangQilu Hospital Of Shandong University Dezhou Hospital, Dezhou, Shandong, China.
Jinkui LiangNMPA Key Laboratory for Quality Evaluation of Medical Materials and Biological Protective Devices, Shandong Institute of Medical Device and Pharmaceutical Packaging Inspection, Shandong, Jinan, China.
Zechen LinNMPA Key Laboratory for Quality Evaluation of Medical Materials and Biological Protective Devices, Shandong Institute of Medical Device and Pharmaceutical Packaging Inspection, Shandong, Jinan, China.
Xubin ZhangQilu Hospital Of Shandong University Dezhou Hospital, Dezhou, Shandong, China.
Finxin DuSchool of Mechanical Engineering, Shandong University, Jinan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: In the field of orthopedic surgery, the notched continuum robot has garnered significant attention due to its passive compliance, making it particularly suitable for procedures in complex and delicate bone and joint regions. However, accurately modeling the notched continuum robot remains a significant challenge. Methods: This paper proposes a high-precision mechanical modeling method for the notched continuum robot to address this issue. The flexible beam deflection prediction model based on the beam constraint model is established. The force balance friction model considering internal friction is established. An accurate static model is obtained, which can accurately estimate the deformation and deflection behavior of the robot according to the input driving force. The kinematic model of the notched continuum robot based on the static model is established. This method achieves high accuracywhile ensuring computational efficiency. Results: Experimental results demonstrate that the static model's error is only 0.1629 mm, which corresponds to 0.25% of the total length of the continuum robot, which is 66 mm. Discussion: This research provides valuable insights into the modeling and control of continuum robots and holds significant implications for advancing precision in orthopedic surgery.

Indexed as

beam constraint modelbeam deflection prediction modelkinematicsmechanical modelingnotched continuum robotorthopedic surgery

Identifiers

PMID39473928
PMCPMC11518810

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.