Evidence map›Paper›PMID 39473501›Full record

ArticleFrontiers in medicine2024

Accuracy of intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in short and long eyes.

Pedro Tañá-Rivero, Paz Orts-Vila, Pedro Tañá-Sanz, Santiago Tañá-Sanz, Ramón Ruiz-Mesa, Robert Montés-Micó

Abstract read
In one paragraph

Article in Frontiers in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Pedro Tañá-RiveroOftalvist, Alicante, Spain.
Paz Orts-VilaOftalvist, Alicante, Spain.
Pedro Tañá-SanzOftalvist, Alicante, Spain.
Santiago Tañá-SanzOftalvist, Alicante, Spain.
Ramón Ruiz-MesaOftalvist, Jerez de la Frontera, Spain.
Robert Montés-MicóOptics and Optometry and Vision Sciences Department, University of Valencia, Valencia, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: To compare the accuracy of intraoperative wavefront aberrometry using the ORA VLynk system with different biometry-based formulas in short and long eyes after cataract surgery. Methods: This prospective study considered 48 eyes with axial lengths of <22.1 mm and 48 eyes with axial lengths of >25.0 mm. All eyes were implanted with the monofocal AcrySof IQ IOL, the power being determined using the ORA VLynk. The postoperative spherical equivalent (SE) at 3 months was compared to that predicted preoperatively using the SRK/T, Hoffer Q, Haigis, Holladay 2, Barrett Universal II, and Barrett True K formulas and intraoperatively using the ORA VLynk. Mean numerical and absolute errors and the percentage of eyes within ±0.50 D/1.00 D of their target were obtained. Results: For long eyes, the mean absolute error values were 0.35, 0.52, 0.34, 0.30, 0.29, 0.27, and 0.24D for SRK/T, Hoffer Q, Haigis, Holladay 2, Barrett Universal II, Barrett True K, and ORA VLynk, respectively ( Conclusion: The ORA VLynk performs better than all biometry-based formulas in long eyes and, in short eyes, it is as effective as SRK/T, Haigis, Barrett Universal II, and Barrett true K, with the Hoffer Q and Holladay 2 being the most accurate; however, the differences between the calculation methods were small. Clinical trial registration: Identifier DRKS000028106.

Indexed as

cataractintraocular lensintraoperative aberrometrylongphacoemulsificationshort

Identifiers

PMID39473501
PMCPMC11518733

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked