Evidence map›Paper›PMID 39473443›Full record

ArticleAdvanced optical materials2024

Spatially-coded Fourier ptychography: flexible and detachable coded thin films for quantitative phase imaging with uniform phase transfer characteristics.

Ruihai Wang, Liming Yang, Yujin Lee, Kevin Sun, Kuangyu Shen, Qianhao Zhao, Tianbo Wang, Xincheng Zhang, Jiayi Liu, Pengming Song and 1 more

Abstract read
In one paragraph

Article in Advanced optical materials, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Metasurface-based Fourier ptychographic microscopy.Nanophotonics (Berlin, Germany) · 2025
    Article
  2. Multiscale aperture synthesis imager.Nature communications · 2025
    Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Ptychography at all wavelengths.Nature reviews. Methods primers · 2025
    Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Ruihai WangDepartment of Biomedical Engineering, University of Connecticut, Storrs, USA.
Liming YangDepartment of Biomedical Engineering, University of Connecticut, Storrs, USA.
Yujin LeeSchool of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea.
Kevin SunAndover High School, Andover, USA.
Kuangyu ShenDepartment of Chemical and Biomolecular Engineering, University of Connecticut, Storrs, USA.
Qianhao ZhaoDepartment of Biomedical Engineering, University of Connecticut, Storrs, USA.
Tianbo WangDepartment of Biomedical Engineering, University of Connecticut, Storrs, USA.
Xincheng ZhangDepartment of Biomedical Engineering, University of Connecticut, Storrs, USA.
Jiayi LiuFarmington High School, Farmington, USA.
Pengming SongDepartment of Biomedical Engineering, University of Connecticut, Storrs, USA.
Guoan ZhengDepartment of Biomedical Engineering, University of Connecticut, Storrs, USA.

Funding

Label-free digital cytopathology using deep-ultraviolet coded ptychography with intrinsic molecular contrastR01EB034744 · NIBIB · UNIVERSITY OF CONNECTICUT STORRS · PI Guoan Zheng · 2023 to 2026
$1.4M
NIBIB NIH HHS R01 EB034744
6 · The paper itself

Abstract

Fourier ptychography (FP) is an enabling imaging technique that produces high-resolution complex-valued images with extended field coverages. However, when FP images a phase object with any specific spatial frequency, the captured images contain only constant values, rendering the recovery of the corresponding linear phase ramp impossible. This challenge is not unique to FP but also affects other common microscopy techniques -- a rather counterintuitive outcome given their widespread use in phase imaging. The underlying issue originates from the non-uniform phase transfer characteristic inherent in microscope systems, which impedes the conversion of object wavefields into discernible intensity variations. To address this challenge, we present spatially-coded Fourier ptychography (scFP), a new method that synergizes FP with spatial-domain coded detection for true quantitative phase imaging. In scFP, a flexible and detachable coded thin film is attached atop the image sensor in a regular FP setup. The spatial modulation of this thin film ensures a uniform phase response across the entire synthetic bandwidth. It improves reconstruction quality and corrects refractive index underestimation issues prevalent in conventional FP and related tomographic implementations. The inclusion of the coded thin film further adds a new dimension of measurement diversity in the spatial domain. The development of scFP is expected to catalyse new research directions and applications for phase imaging, emphasizing the need for true quantitative accuracy with uniform frequency response.

Indexed as

coded detectioncomputational microscopyphase retrievalphase transfer functionQuantitative phase imaging

Identifiers

PMID39473443
PMCPMC11521390

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.