Evidence map›Paper›PMID 39471491›Full record

ArticleEuropean journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery2024

Finite element analysis and computational fluid dynamics to elucidate the mechanism of distal stent graft-induced new entry after frozen elephant trunk technique.

Shinri Morodomi, Homare Okamura, Yoshihiro Ujihara, Shukei Sugita, Masanori Nakamura

Abstract read
In one paragraph

Article in European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Shinri MorodomiDepartment of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Aichi, Japan.
Homare OkamuraDepartment of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, Saitama, Japan.ORCID 0000-0002-8806-5110
Yoshihiro UjiharaDepartment of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Aichi, Japan.
Shukei SugitaDepartment of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Aichi, Japan.
Masanori NakamuraDepartment of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Aichi, Japan.

Funding

Japan Agency for Medical Research and Development JK240100Japan Society for the Promotion of Science KAKENHI JP23K08260Ministry of Education, Culture, Sports, Science and Technology, Japan
6 · The paper itself

Abstract

objectivesDistal stent graft-induced new entry (dSINE), a new intimal tear at the distal edge of the frozen elephant trunk (FET), is a complication of FET. Preventive measures for dSINE have not yet been established. This study aimed to clarify the mechanisms underlying the development of dSINE by simulating the mechanical environment at the distal edge of the FET.

methodsThe stress field in the aortic wall after FET deployment was calculated using finite element analysis. Blood flow in the intraluminal space of the aorta and FET models was simulated using computational fluid dynamics. The simulations were conducted with various oversizing rates of FET ranging from 0 to 30% under the condition of FET with elastic recoil.

resultsThe elastic recoil of the FET, which caused its distal edge to push against the greater curvature of the aorta, induced a concentration of circumferential stress and increased wall shear stress (WSS) at the aorta. Elastic recoil also created a discontinuous notch on the lesser curvature of the aorta, causing flow stagnation. An increase in the oversizing rate of the FET widened the large circumferential stress area on the greater curvature and increases the maximum stress. Conversely, a decrease in the oversizing rate of the FET increased the WSS and widened the area with high WSS.

conclusionsCircumferential stress concentration due to an oversized FET and high WSS due to an undersized FET can cause a dSINE. The selection of smaller-sized FET alone might not prevent dSINE.

Indexed as

Finite Element AnalysisHydrodynamicsModels, CardiovascularStentsAortaBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationComputer SimulationHumansStress, MechanicalFrozen elephant trunkSimulationStent graft-induced new entry

Identifiers

PMID39471491
PMCPMC11568347

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.