Evidence map›Paper›PMID 39470833›Full record

ArticleWorld journal of urology2024

Implementation of surgical rehearsal utilizing patient specific hydrogel kidney phantoms prior to complex renal cancer surgery: a pilot study.

Ahmed Ghazi, Patrick Saba, Nathan Shuler, Lauren Shepard, Tyler Holler, Ahmed Radwan, Hani Rashid

Abstract read
PubMed Publisher
In one paragraph

Article in World journal of urology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ahmed GhaziBrady Urological Institute, Johns Hopkins University, Baltimore, MD, USA. Aghazi1@jh.edu.ORCID http://orcid.org/0000-0002-4325-1446
Patrick SabaSurgical Learning and Innovation Center of Excellence , Johns Hopkins University, Baltimore, MD, USA.
Nathan ShulerSurgical Learning and Innovation Center of Excellence , Johns Hopkins University, Baltimore, MD, USA.
Lauren ShepardSurgical Learning and Innovation Center of Excellence , Johns Hopkins University, Baltimore, MD, USA.ORCID http://orcid.org/0000-0002-0926-1587
Tyler HollerDepartment of Surgery, University of Rochester Medical Center, Rochester, NY, USA.
Ahmed RadwanDepartment of Urology, Ain-Shams University, Cairo, Egypt.
Hani RashidDepartment of Urology, University of Rochester Medical Center, Rochester, NY, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionWith the advancement of surgical technology, the opportunity to integrate novel surgical preparation is imperative to improve patient outcomes and enhance safety.

methodsPatient specific perfused kidney phantoms including the tumor, parenchyma, artery, vein, and calyx were fabricated using 3D-printing and hydrogel injection molding from scans of 25 patients scheduled for robotic partial-nephrectomy (RAPN). Models are validated for anatomical accuracy, mechanical, functional properties and surrounded by the other models of relevant anatomy in a body cast for a simulated surgical rehearsal. We investigated the impact of these preoperative rehearsals preceding complex RAPN by analyzing changes in surgeons' decisions following review of both axial-imaging and following rehearsal simulation. Predictive ability of these rehearsal platforms was compared to live surgery outcomes and trifecta of cases as an outcome was calculated.

results25 patients with complex renal tumors, average 9.8 nephrometry score and 4.9 cm mean tumor diameter were consented. Mean blood loss and WIT were 193.2 ml and 19.8 min. Two Clavien 2 complications were reported at 30-day postoperative. Trifecta was achieved in 17 (68%) of surgical cases. Surgeons' confidence in their ability to complete a partial nephrectomy and ability to predict WIT significantly increased from initial viewing the axial imaging to after the rehearsal. The correlation coefficient between the procedural clinical data collected during the rehearsals and live surgery were calculated.

conclusionThe application of this versatile method for creating authentic perfused kidney phantoms can result in increased confidence in surgical plan and thus improved surgical performance and outcomes.

Indexed as

HydrogelsKidney NeoplasmsNephrectomyPhantoms, ImagingRobotic Surgical ProceduresAgedFemaleHumansKidneyMaleMiddle AgedPilot ProjectsPrinting, Three-DimensionalHydrogelsComplex renal massPatient-specific simulationRobotic partial nephrectomySimulationSurgical Rehearsal

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.