In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Fatemeh AhadiFaculty of Mechanical Engineering, Semnan University, Semnan, Iran.
Mohammad AzadiFaculty of Mechanical Engineering, Semnan University, Semnan, Iran.
Mojtaba BiglariFaculty of Mechanical Engineering, Semnan University, Semnan, Iran.
Mahdi BodaghiDepartment of Engineering, School of Science and Technology, Nottingham Trent University, Nottingham, United Kingdom.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the present study, the impact of geometric variables and structural features of stents on hemodynamic parameters is investigated. Intravascular stent implantation is a treatment method whose success largely depends on the geometric structure of the stent and its effect on hemodynamic parameters. Medical devices called stents are inserted into arteries to restore blood flow when an artery is blocked. In this research, an optimal stent was designed and its effect compared to the common commercial stent used for coronary arteries was investigated and compared. It has been found that the geometry of the stent has an effective impact on the wall shear stress in the stented artery. Therefore, in this article, the importance of stent structures in the treatment of the coronary artery disease is discussed. For this purpose, first, an optimal stent is created with the topology optimization technique to find the best structure in the stent design. Finally, the optimized stent is numerically verified with ANSYS software and compared with existing commercial stents, and then the prototype is fabricated using additive manufacturing techniques. Commercial software ABAQUS, SolidWorks, and ANSYS are used in this research. The results showed that in optimizing a square plate, a sample with a minimum residual volume limit equal to 10 and 7 % can be selected as the optimal state. The results indicate that the new design can improve the distribution of wall shear stresses to reduce the adverse hemodynamic changes. Therefore, the proposed stent geometric structure can help improve the treatment. Finally, the optimized stent along with a commercial stent was made with the 3D printing method.

Indexed as

3D printingComputational fluid dynamicsHemodynamicStentTopology optimization

Identifiers

PMID39469694
PMCPMC11513526

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.