Evidence map›Paper›PMID 39469423›Full record

ReviewBJA open2024

Oxygen insufflation via the working channel during tracheal intubation guided by a flexible optical scope and benefits, dangers, and future of the method: a narrative review.

Alexandre Garioud, Michael Seltz Kristensen

Registry-linked trialAbstract readReview
In one paragraph

Review in BJA open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06680648 (Oxygen Insufflation Via a Flexible Scope to Remove Secretions and Blood Obstructiong the View When Advancing the Scope Towrds the Trachea), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06680648 nanot yet recruitingnot on this map

Oxygen Insufflation Via a Flexible Scope to Remove Secretions and Blood Obstructiong the View When Advancing the Scope Towrds the Trachea

TypeinterventionalSponsorRigshospitalet, DenmarkRan2024 to 2024Enrolled64ConditionsInsertion of a Flexible Bronchoscope, Airway Management When Secretions Obstruct the LarynxArmsaddition of oxygeninsufflation via working channel of flexible scope, no-oxygen insufflation
3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Safer oxygenation through flexible optical scopes during airway management: an in vitro study.Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2025
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Alexandre GarioudDepartment of Anaesthesia, Centre of Head and Orthopaedics, Rigshospitalet, University Hospital of Copenhagen, Copenhagen, Denmark.
Michael Seltz KristensenDepartment of Anaesthesia, Centre of Head and Orthopaedics, Rigshospitalet, University Hospital of Copenhagen, Copenhagen, Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

When performing tracheal intubation guided by a flexible optical scope, the operator may lose the anatomical orientation and hypoxia may occur. Oxygen insufflation through the working channel of the flexible optical scope is used by anaesthetists to prevent blurring of the lens and to prevent hypoxia. However, fatal iatrogenic injuries from this method are reported. Our aim is to review the current literature on oxygen insufflation through the working channel during tracheal intubation guided by a flexible optical scope, to identify its benefits and the source of its dangers, and ultimately to provide a basis for the development of a safer technique. We conducted a literature search of databases, guidelines, and textbooks using search terms related to oxygen insufflation through the working channel during intubation guided by a flexible optical scope. Clinical trials confirm that the technique results in better visibility and better oxygenation during intubation. Gastric rupture and pneumothorax were the most frequent types of injury. We identified that oxygen insufflation without pressure limitation during accidental misplacement of the flexible optical scope in the oesophagus, deep in the lower airways, or via a tear of the airway mucosa was the cause of barotrauma. We conclude that a delivered pressure below 40 cm H

Indexed as

Anticipated difficult airway managementFlexible opticalIntubationOxygen insufflationWorking channel

Identifiers

PMID39469423
PMCPMC11513500

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.