ArticleJournal of magnetic resonance imaging : JMRI2025
Repeatability, Reproducibility, and Observer Variability of Cortical T1 Mapping for Renal Tissue Characterization.
Article in Journal of magnetic resonance imaging : JMRI, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- ASL, DTI, and T1 mapping in identifying immune and non-immune pathogenic factors of chronic allograft injury.Quantitative imaging in medicine and surgery · 2026Article
- Intra- and interobserver variability in renal multiparametric magnetic resonance imaging: T1 mapping, diffusion-weighted imaging, arterial spin labeling, blood oxygen level-dependent and renal artery flow measurements utilizing manual segmentation.Quantitative imaging in medicine and surgery · 2026Article
- Multiparametric functional MRI for early detection of renal impairment: clinical applications and future directions.Abdominal radiology (New York) · 2026Review
- Multi-scanner repeatability and reproducibility of qRF-MRF breath-held and free-breathing with pilot tone in the abdomen.Magma (New York, N.Y.) · 2026Article
- Scan-rescan reproducibility and interobserver reliability of T1 and T2 measurements of extraocular muscles using a multi-dynamic multi-echo MRI sequence.BMC medical imaging · 2026Article
- Influence of Field Strength, Sex, and Age on Pseudo-Continuous Arterial Spin Labeling and TJournal of magnetic resonance imaging : JMRI · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe global rise in kidney diseases underscores the need for reliable, noninvasive imaging biomarkers. Among these, renal cortical T1 has shown promise but further technical validation is still required. PURPOSE: To evaluate the repeatability, reproducibility, and observer variability of kidney cortical T1 mapping in human volunteers without known renal disease. STUDY TYPE: Prospective. SUBJECTS: Three cohorts without renal disease: 1) 25 volunteers (median age 38 [interquartile range, IQR: 28-42] years, female N = 11) for scan-rescan assessments on GE 1.5 T and Siemens 1.5 T; 2) 29 volunteers (median age 29 [IQR: 24-40] years, female N = 15) for scan-rescan assessments on Siemens 3 T; and 3) 16 volunteers (median age 34 [IQR: 31-42] years, female N = 8) for cross-scanner reproducibility. FIELD STRENGTH/SEQUENCES: 1.5 T and 3 T, a modified Look-Locker imaging (MOLLI) sequence with a balanced steady-state free precession (bSSFP) readout. ASSESSMENT: Kidney cortical T1 data was acquired on GE 1.5 T scanner, Siemens 1.5 T and 3 T scanners. Within-scanner repeatability and inter/intra-observer variability: GE 1.5 T and Siemens 1.5 T, and cross-scanner manufacturer reproducibility: Siemens 1.5 T-GE 1.5 T. STATISTICAL TESTS: Bland Altman analysis, coefficient of variation (CoV), intra-class coefficient (ICC), and repeatability coefficient (RC).
resultsRenal cortical T1 mapping showed high repeatability and reliability across scanner field strengths and manufacturers (repeatability: CoV 1.9%-2.8%, ICC 0.79-0.88, pooled RC 73 msec; reproducibility: CoV 3.0%, ICC 0.75, RC 90 msec). The method also showed robust observer variability (CoV 0.6%-1.4%, ICC 0.93-0.98, RC 22-48 msec). DATA
conclusionKidney cortical T1 mapping is a highly repeatable and reproducible method across MRI manufacturers, field strengths, and observer conditions. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.