Evidence map›Paper›PMID 39466570›Full record

ArticleJournal of cardiovascular translational research2025

Mechanical and Geometric Characterization of a Novel 2-Ply Vacuum-Pressed Biological Scaffold Patch Design for Posterior Mitral Valve Reconstruction.

Johannes H Jedrzejczyk, Frederik T Andersen, Jacob Petersen, Alexander Emil Kaspersen, Urjosee Sahana, Søren N Skov, Jens T Væsel, J Michael Hasenkam, Marcell J Tjørnild

Abstract readComparative Study
In one paragraph

Article in Journal of cardiovascular translational research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Johannes H JedrzejczykDepartment of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark. johjed@clin.au.dk.ORCID 0000-0001-5029-9117
Frederik T AndersenDepartment of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark.ORCID 0009-0000-5605-1673
Jacob PetersenDepartment of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark.
Alexander Emil KaspersenDepartment of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark.ORCID 0000-0002-6088-5248
Urjosee SahanaDepartment of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark.
Søren N SkovDepartment of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark.ORCID 0000-0003-2352-853X
Jens T VæselDepartment of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark.
J Michael HasenkamDepartment of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark.ORCID 0000-0001-7960-1172
Marcell J TjørnildDepartment of Clinical Medicine, Aarhus University, Aarhus, Denmark.ORCID 0000-0002-4772-4319

Funding

Novo Nordisk Fonden NNF20OC0065584
6 · The paper itself

Abstract

To assess the mechanical properties of small intestinal submucosal extracellular matrix (SIS-ECM) iterations and choose the optimal version for evaluating functional geometrics after posterior mitral valve reconstruction. Four SIS-ECM versions (2- and 4-ply vacuum-pressed and lyophilized) underwent uniaxial tensile testing. A posterior mitral valve reconstruction patch was developed based on MRI scans (n = 5). Posterior mitral valve reconstruction using 2-ply vacuum-pressed SIS-ECM was performed (n = 7), and geometrics were evaluated using a modified left heart simulator. The vacuum-pressed iterations displayed superior maximum stress values compared to lyophilized (2-ply: median [IQR], 15.8 [15.2-19.0] vs 7.9 [7.3-8.3] MPa, p < 0.001; 4-ply: median (IQR), 15.8 -[14.6-22.0] vs 7.9 [7.6-8.4] MPa). All reconstructed valves were competent with preserved total leaflet area, but individual leaflet segment areas were redistributed. Posterior mitral valve reconstruction with our 2-ply vacuum-pressed SIS-ECM patch design was feasible in vitro. Further in vivo evaluation is warranted.

Indexed as

BioprosthesisHeart Valve ProsthesisHeart Valve Prosthesis ImplantationMitral ValveTissue ScaffoldsBiomechanical PhenomenaHumansMaleMaterials TestingProsthesis DesignStress, MechanicalTensile StrengthVacuumLyophilizedMitral valve reconstructionMitral valve repairPosterior mitral valve leafletSmall intestinal submucosal extracellular matrixVacuum-pressed

Identifiers

PMID39466570
PMCPMC12043767

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.