A rate-responsive duty-cycling protocol for leadless pacemaker synchronization.

Adrian Ryser, Tobias Reichlin, Jürgen Burger, Thomas Niederhauser, Andreas Haeberlin

Abstract read
In one paragraph

Article in Biomedical engineering letters, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Adrian RyserDepartment of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 20, 3010 Bern, BE Switzerland.ORCID 0000-0001-7981-2009
Tobias ReichlinDepartment of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 20, 3010 Bern, BE Switzerland.
Jürgen BurgerSchool of Biomedical and Precision Engineering, University of Bern, Güterstrasse 24/26, 3008 Bern, BE Switzerland.
Thomas NiederhauserInstitute for Human Centered Engineering HuCE, Bern University of Applied Sciences, Quellgasse 21, 2501 Biel, BE Switzerland.
Andreas HaeberlinDepartment of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 20, 3010 Bern, BE Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Dual-chamber leadless pacemakers (LLPMs) consist of two implants, one in the right atrium and one in the right ventricle. Inter-device communication, required for atrioventricular (AV) synchrony, however, reduces the projected longevity of commercial dual-chamber LLPMs by 35-45%. This work analyzes the power-saving potential and the resulting impact on AV-synchrony for a novel LLPM synchronization protocol. Relevant parameters of the proposed window scheduling algorithm were optimized with system-level simulations investigating the resulting trade-off between transceiver current consumption and AV-synchrony. The parameter set included the algorithm's setpoint for the target number of windows per cardiac cycle and the number of averaging cycles used in the window update calculation. The sensing inputs for the LLPM model were derived from human electrocardiogram recordings in the MIT-BIH Arrhythmia Database. Transceiver current consumption was estimated by combining the simulation results on the required communication resources with electrical measurements of a receiver microchip developed for LLPM synchronization in previous work. The performance ratio given by AV-synchrony divided by current consumption was maximized for a target of one window per cardiac cycle and three averaging cycles. Median transceiver current of both LLPMs combined was 166 nA (interquartile range: 152-183 nA) and median AV-synchrony was 92.5%. This corresponded to median reduction of 18.3% and 3.2% in current consumption and AV-synchrony, respectively, compared to a non-rate-responsive implementation of the same protocol, which prioritized maximum AV-synchrony. In conclusion, adopting a rate-responsive communication protocol may significantly increase device longevity of dual-chamber LLPMs without compromising AV-synchrony, potentially reducing the frequency of device replacements.

Indexed as

Communication protocolDual-chamber pacemakeri2iImplant communicationLeadless pacemakerRate-responsive

Identifiers

PMID39465113
PMCPMC11502617

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.