Evidence map›Paper›PMID 39464647›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2024

Fluoroscopic Procedure-Room Scatter-Dose Reduction Using a Region-of-Interest (ROI) Attenuator.

Martina P Orji, Kyle Williams, S V Setlur Nagesh, Stephen Rudin, Daniel R Bednarek

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Martina P OrjiThe State University of New York at Buffalo, Jacobs School of Medicine and Biomedical Sciences, Canon Stroke and Vascular Research Center, 875 Ellicott St., Buffalo, NY 14203.
Kyle WilliamsThe State University of New York at Buffalo, Jacobs School of Medicine and Biomedical Sciences, Canon Stroke and Vascular Research Center, 875 Ellicott St., Buffalo, NY 14203.
S V Setlur NageshThe State University of New York at Buffalo, Jacobs School of Medicine and Biomedical Sciences, Canon Stroke and Vascular Research Center, 875 Ellicott St., Buffalo, NY 14203.
Stephen RudinThe State University of New York at Buffalo, Jacobs School of Medicine and Biomedical Sciences, Canon Stroke and Vascular Research Center, 875 Ellicott St., Buffalo, NY 14203.
Daniel R BednarekThe State University of New York at Buffalo, Jacobs School of Medicine and Biomedical Sciences, Canon Stroke and Vascular Research Center, 875 Ellicott St., Buffalo, NY 14203.

Funding

High Speed Angiography at 1000 frames per secondR01EB030092 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2020 to 2023
$2.6M
NIBIB NIH HHS R01 EB030092
6 · The paper itself

Abstract

During fluoroscopically-guided interventional (FGI) procedures, dose to the patient as well as the scatter dose to staff can be high. However, a significant dose reduction can be possible by using a region-of-interest (ROI) attenuator that reduces the x-ray intensity in the peripheral x-ray field while providing full field of view imaging. In this work, we investigated the magnitude of scatter dose reduction to staff made possible by using an ROI attenuator composed of 0.7 mm Cu with a central circular hole that projected a 5.4 cm ROI onto a Kyoto anthropomorphic phantom in the head, chest, and abdomen regions. A 150-cc ionization chamber was placed on a stand at a height of 150 cm (eye level) from the floor and 25 cm and 50 cm lateral distance from the gantry isocenter in a direction perpendicular to the table centerline to measure scatter dose at different positions along the length of the table. Scatter dose per entrance air kerma (mGy/Gy) was measured with and without the ROI attenuator and the percent scatter reduction for the ROI attenuator was determined as a function of staff positions, beam energy and gantry angulation. For head imaging, the measured percent dose reduction was 50%-65% and, for chest and abdomen imaging, the scatter dose reduction was 63%-72% at 50 cm lateral distance when using this ROI attenuator with about 20% beam transmission at 80 kVp. Overall, a considerable reduction of scattered radiation in the interventional room can be realized using an ROI attenuator.

Indexed as

Fluoroscopically-guided interventional procedureoccupational exposureradiation safetyROI Imagingscatter-dose reduction

Identifiers

PMID39464647
PMCPMC11512733

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.