Evidence map›Paper›PMID 39464130›Full record

ArticlebioRxiv : the preprint server for biology2024

From Simulations to Inference: Using Machine Learning to Tune Patient-Specific Finite-Element Models of the Middle Ear Towards Objective Diagnosis.

Hamid Motallebzadeh, Michael Deistler, Florian M Schönleitner, Jakob H Macke, Sunil Puria

Abstract readPreprint
In one paragraph

Article in bioRxiv : the preprint server for biology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hamid MotallebzadehDepartment of Communication Sciences and Disorders, California State University, Sacramento, CA, USA.
Michael DeistlerMachine Learning in Science, University of Tübingen, Germany.
Florian M SchönleitnerNeuroengineering - Elite Master Program, TUM School of Computation, Information and Technology, Technical University of Munich, Germany.
Jakob H MackeMachine Learning in Science, University of Tübingen, Germany.ORCID 0000-0001-5154-8912
Sunil PuriaEaton-Peabody Laboratories, Massachusetts Eye and Ear.

Funding

Objective and noninvasive diagnosis of middle-ear and conductive pathologies using simulation-based inference and transfer learning applied to clinical dataR21DC020274 · NIDCD · MASSACHUSETTS EYE AND EAR INFIRMARY · PI MOTALLEBZADEH, HAMID · 2022 to 2024
$549k
NIDCD NIH HHS R21 DC020274
6 · The paper itself

Abstract

Computational models, particularly finite-element (FE) models, are essential for interpreting experimental data and predicting system behavior, especially when direct measurements are limited. A major challenge in tuning these models is the large number of parameters involved. Traditional methods, such as one-by-one sensitivity analyses, are time-consuming, subjective, and often return only a single set of parameter values, focusing on reproducing averaged data rather than capturing the full variability of experimental measurements. In this study, we applied simulation-based inference (SBI) using neural posterior estimation (NPE) to tune an FE model of the human middle ear. The training dataset consisted of 10,000 FE simulations of stapes velocity, ear-canal (EC) input impedance, and absorbance, paired with seven FE parameter values randomly sampled within plausible ranges. The neural network learned the association between parameters and simulation outcomes, returning the probability distribution of parameter values that can reproduce experimental data. Our approach successfully identified parameter sets that reproduced three experimental datasets simultaneously. By accounting for experimental noise and variability during training, the method provided a probability distribution of parameters, representing all valid combinations that could fit the data, rather than tuning to averaged values. The network demonstrated robustness to noise and exhibited an efficient learning curve due to the large training dataset. SBI offers an objective alternative to laborious sensitivity analyses, providing probability distributions for each parameter and uncovering interactions between them. This method can be applied to any biological FE model, and we demonstrated its effectiveness using a middle-ear model. Importantly, it holds promise for objective differential diagnosis of conductive hearing loss by providing insight into the mechanical properties of the middle ear.

Identifiers

PMID39464130
PMCPMC11507950

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.