Evidence map›Paper›PMID 39463806›Full record

ArticleIEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation2024

Fully Distributed Shape Sensing of a Flexible Surgical Needle Using Optical Frequency Domain Reflectometry for Prostate Interventions.

Jacynthe Francoeur, Dimitri Lezcano, Yernar Zhetpissov, Raman Kashyap, Iulian Iordachita, Samuel Kadoury

Abstract read
In one paragraph

Article in IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Device-Specific Calibration Methods for Optical Frequency Domain Reflectometry-Based Shape Sensing in Catheters and Surgical Needles.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jacynthe FrancoeurDepartment of Electrical Engineering, Polytechnique Montréal, Montréal, QC H3T1J4, Canada.
Dimitri LezcanoDepartment of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
Yernar ZhetpissovDepartment of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
Raman KashyapDepartments of Electrical Engineering and Physics Engineering, Polytechnique Montréal, Montréal, QC H3T1J4, Canada.
Iulian IordachitaDepartment of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
Samuel KadouryDepartment of Computer and Software Engineering, Polytechnique Montréal, Montréal, QC H3T1J4, Canada.

Funding

Adaptive Percutaneous Prostate Interventions using Sensorized NeedleR01CA235134 · NCI · BRIGHAM AND WOMEN'S HOSPITAL · PI Nobuhiko Hata, IULIAN IOAN IORDACHITA · 2019 to 2026
$3.6M
NCI NIH HHS R01 CA235134
6 · The paper itself

Abstract

In minimally invasive procedures such as biopsies and prostate cancer brachytherapy, accurate needle placement remains challenging due to limitations in current tracking methods related to interference, reliability, resolution or image contrast. This often leads to frequent needle adjustments and reinsertions. To address these shortcomings, we introduce an optimized needle shape-sensing method using a fully distributed grating-based sensor. The proposed method uses simple trigonometric and geometric modeling of the fiber using optical frequency domain reflectometry (OFDR), without requiring prior knowledge of tissue properties or needle deflection shape and amplitude. Our optimization process includes a reproducible calibration process and a novel tip curvature compensation method. We validate our approach through experiments in artificial isotropic and inhomogeneous animal tissues, establishing ground truth using 3D stereo vision and cone beam computed tomography (CBCT) acquisitions, respectively. Our results yield an average RMSE ranging from 0.58 ± 0.21 mm to 0.66 ± 0.20 mm depending on the chosen spatial resolution, achieving the submillimeter accuracy required for interventional procedures.