Dosimetric optimization for dynamic mixed beam arc therapy (DYMBARC).

Chengchen Zhu, Gian Guyer, Jenny Bertholet, Silvan Mueller, Hannes A Loebner, Werner Volken, Julius Arnold, Daniel M Aebersold, Marco F M Stampanoni, Michael K Fix and 1 more

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Chengchen ZhuDivision of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland.ORCID https://orcid.org/0009-0006-3506-8998
Gian GuyerDivision of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland.ORCID https://orcid.org/0009-0002-8880-2069
Jenny BertholetDivision of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland.ORCID https://orcid.org/0000-0003-0930-1531
Silvan MuellerDivision of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland.ORCID https://orcid.org/0000-0002-9835-4362
Hannes A LoebnerDivision of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland.ORCID https://orcid.org/0000-0002-8439-2464
Werner VolkenDivision of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland.
Julius ArnoldDepartment of Physics, ETH Zürich, Zürich, Switzerland.
Daniel M AebersoldDivision of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland.ORCID https://orcid.org/0000-0002-9493-3834
Marco F M StampanoniInstitute for Biomedical Engineering, ETH Zürich and PSI, Villigen, Switzerland.ORCID https://orcid.org/0000-0001-7486-6681
Michael K FixDivision of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland.ORCID https://orcid.org/0000-0002-3911-3403
Peter ManserDivision of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland.ORCID https://orcid.org/0000-0003-3225-8025

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundNon-coplanarity and mixed beam modality could be combined to further enhance dosimetric treatment plan quality. We introduce dynamic mixed beam arc therapy (DYMBARC) as an innovative technique that combines non-coplanar photon and electron arcs, dynamic gantry and collimator rotations, and intensity modulation with photon multileaf collimator (MLC). However, finding favorable beam directions for DYMBARC is challenging due to the large solution space, machine component constraints, and optimization parameters, posing a highly non-convex optimization problem. PURPOSE: To establish DYMBARC and solve the pathfinding challenge by employing direct aperture optimization (DAO) to determine the table angles and gantry angle ranges of photon and electron arcs for different clinically motivated cases.

methodsThe method starts by generating a grid of beam directions based on user-defined resolutions along the gantry and table angle axes for each beam quality considered. Beam directions causing collisions or entering through the end of CT are excluded. For electrons, a fixed source-to-surface distance of 80 cm is used to reduce in-air scatter. Electron beam energies with insufficient range to reach the target or beam directions impinging on the table before reaching the patient are excluded. The remaining beam directions form the pathfinding solution space. Promising photon and electron MLC-defined apertures, with associated monitor unit (MU) weights, are iteratively added using a hybrid-DAO algorithm. This algorithm combines column generation to add apertures and simulated annealing to further refine aperture shapes and weights. Apertures are added until the requested number of paths are formed and the user-defined maximum total gantry angle range is reached. Paths are resampled to a finer gantry angle resolution and subject to DAO for simultaneous optimization of beam intensities along the photon/electron arcs. Subsequent final dose calculation and MU weight reoptimization result in a deliverable DYMBARC plan. DYMBARC plans are created for three clinically motivated cases (brain, breast, and pelvis) and compared to DYMBARC variants: colli-DTRT (dynamic collimator trajectory radiotherapy) using non-coplanar photon arcs; and Arc-MBRT (mixed beam radiotherapy) using photons and electrons but restricted to coplanar setup. Additionally, a manually defined volumetric modulated arc therapy (VMAT) setup serves as a reference clinical technique. Dose distributions, dose-volume histograms, and dosimetric endpoints are evaluated. Dosimetric validation with radiochromic film measurements (gamma evaluation, 3% / 2 mm (global), 10% dose threshold) is performed on a TrueBeam system in developer mode for one case.

resultsWhile maintaining similar target coverage and homogeneity, DYMBARC reduced mean doses to organs-at-risk compared to VMAT by an average of 3.2, 0.5, and 2.9 Gy for the brain, breast, and pelvis cases, respectively. Similar or smaller mean dose reductions were observed for Arc-MBRT or colli-DTRT, compared to VMAT. Electron contributions to the mean planning target volume dose ranged from 2% to 34% for DYMBARC and from 11% to 40% for Arc-MBRT. Measurement validation showed >99.7% gamma passing rate.

conclusionsDYMBARC was successfully established using a dosimetrically optimized pathfinding approach, combining non-coplanarity with mixed beam modality. DYMBARC facilitated the determination of photon and electron contributions on a case-by-case basis, enhancing more personalized treatment modalities.

Indexed as

RadiometryRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedElectronsHumansPhotonsRadiotherapy Dosagedosimetrically optimized pathfindingmixed beam radiotherapynon‐coplanar radiotherapy

Identifiers

PMID39460998
PMCPMC11700002

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.