ArticleMedical physics2025
Dosimetric optimization for dynamic mixed beam arc therapy (DYMBARC).
Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- A simulation study of a novel spiral volumetric modulated arc therapy for enhanced dose delivery efficiency and quality in radiotherapy.Medical physics · 2026Article
- Treatment planning comparison of focused very high energy electron and volumetric modulated arc therapy.Physics and imaging in radiation oncology · 2026Article
- Simultaneous optimization of multiple plans within one treatment course with dosimetric pathfinding for temporally feathered radiation therapy.Medical physics · 2025Article
- Dosimetric optimization for dynamic mixed beam arc therapy (DYMBARC).Medical physics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundNon-coplanarity and mixed beam modality could be combined to further enhance dosimetric treatment plan quality. We introduce dynamic mixed beam arc therapy (DYMBARC) as an innovative technique that combines non-coplanar photon and electron arcs, dynamic gantry and collimator rotations, and intensity modulation with photon multileaf collimator (MLC). However, finding favorable beam directions for DYMBARC is challenging due to the large solution space, machine component constraints, and optimization parameters, posing a highly non-convex optimization problem. PURPOSE: To establish DYMBARC and solve the pathfinding challenge by employing direct aperture optimization (DAO) to determine the table angles and gantry angle ranges of photon and electron arcs for different clinically motivated cases.
methodsThe method starts by generating a grid of beam directions based on user-defined resolutions along the gantry and table angle axes for each beam quality considered. Beam directions causing collisions or entering through the end of CT are excluded. For electrons, a fixed source-to-surface distance of 80 cm is used to reduce in-air scatter. Electron beam energies with insufficient range to reach the target or beam directions impinging on the table before reaching the patient are excluded. The remaining beam directions form the pathfinding solution space. Promising photon and electron MLC-defined apertures, with associated monitor unit (MU) weights, are iteratively added using a hybrid-DAO algorithm. This algorithm combines column generation to add apertures and simulated annealing to further refine aperture shapes and weights. Apertures are added until the requested number of paths are formed and the user-defined maximum total gantry angle range is reached. Paths are resampled to a finer gantry angle resolution and subject to DAO for simultaneous optimization of beam intensities along the photon/electron arcs. Subsequent final dose calculation and MU weight reoptimization result in a deliverable DYMBARC plan. DYMBARC plans are created for three clinically motivated cases (brain, breast, and pelvis) and compared to DYMBARC variants: colli-DTRT (dynamic collimator trajectory radiotherapy) using non-coplanar photon arcs; and Arc-MBRT (mixed beam radiotherapy) using photons and electrons but restricted to coplanar setup. Additionally, a manually defined volumetric modulated arc therapy (VMAT) setup serves as a reference clinical technique. Dose distributions, dose-volume histograms, and dosimetric endpoints are evaluated. Dosimetric validation with radiochromic film measurements (gamma evaluation, 3% / 2 mm (global), 10% dose threshold) is performed on a TrueBeam system in developer mode for one case.
resultsWhile maintaining similar target coverage and homogeneity, DYMBARC reduced mean doses to organs-at-risk compared to VMAT by an average of 3.2, 0.5, and 2.9 Gy for the brain, breast, and pelvis cases, respectively. Similar or smaller mean dose reductions were observed for Arc-MBRT or colli-DTRT, compared to VMAT. Electron contributions to the mean planning target volume dose ranged from 2% to 34% for DYMBARC and from 11% to 40% for Arc-MBRT. Measurement validation showed >99.7% gamma passing rate.
conclusionsDYMBARC was successfully established using a dosimetrically optimized pathfinding approach, combining non-coplanarity with mixed beam modality. DYMBARC facilitated the determination of photon and electron contributions on a case-by-case basis, enhancing more personalized treatment modalities.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.