ArticleSensors (Basel, Switzerland)2024
A Method for Compensating Hemoglobin Interference in Total Serum Bilirubin Measurement Using a Simple Two-Wavelength Reflectance Photometer.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Neonatal hyperbilirubinemia (NH) is a common condition in newborns, with elevated bilirubin levels potentially causing neurological damage or death. Accurate and timely measurements of total serum bilirubin are essential to prevent these outcomes. Direct spectrophotometry, a reliable method for measuring bilirubin, is particularly useful in constrained settings due to its potential for portable low-cost instrumentation. However, this method is susceptible to interference from hemoglobin, often present due to hemolysis. Typically, this interference is reduced using complex optical filters, reagents, multiple wavelengths, or combinations thereof, which increase costs and complexity while reducing usability. This study presents a hemoglobin compensation algorithm applied to a simple, portable, two-wavelength (465 and 590 nm) reflectance photometer designed to receive 30 µL of plasma or whole blood samples and perform the measurement without any reagents. Testing across five bilirubin and hemoglobin levels (4.96 to 28 mg/dL and 0.06 to 0.99 g/dL, respectively) demonstrated that the algorithm effectively reduces hemoglobin interference and overestimation errors. The overall root mean square error was reduced from 4.86 to 1.45 mg/dL, while the measurement bias decreased from -4.46 to -0.10 mg/dL. This substantial reduction in overestimation errors supports future clinical trials with neonatal blood samples.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.