Evidence map›Paper›PMID 39460129›Full record

ArticleSensors (Basel, Switzerland)2024

A Kernel-Based Calibration Algorithm for Chromatic Confocal Line Sensors.

Ming Qin, Xiao Xiong, Enqiao Xiao, Min Xia, Yimeng Gao, Hucheng Xie, Hui Luo, Wenhao Zhao

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ming QinSchool of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China.
Xiao XiongWuhan Jingce Electronic Group Co., Ltd., Wuhan 430074, China.
Enqiao XiaoWuhan Jingce Electronic Group Co., Ltd., Wuhan 430074, China.
Min XiaSchool of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China.
Yimeng GaoWuhan Jingce Electronic Group Co., Ltd., Wuhan 430074, China.
Hucheng XieWuhan Jingce Electronic Group Co., Ltd., Wuhan 430074, China.ORCID 0009-0001-7323-740X
Hui LuoWuhan Jingce Electronic Group Co., Ltd., Wuhan 430074, China.
Wenhao ZhaoSchool of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In chromatic confocal line sensors, calibration is usually divided into peak extraction and wavelength calibration. In previous research, the focus was mainly on peak extraction. In this paper, a kernel-based algorithm is proposed to deal with wavelength calibration, which corresponds to the mapping relationship between peaks (i.e., the wavelengths) in image space and profiles in physical space. The primary component of the mapping function is depicted using polynomial basis functions, which are distinguished along various dispersion axes. Considering the unknown distortions resulting from field curvature, sensor fabrication and assembly, and even the inherent complexity of dispersion, a typical kernel trick-based nonparametric function element is introduced here, predicated on the notion that similar processes conducted on the same sensor yield comparable distortions.To ascertain the performance with and without the kernel trick, we carried out wavelength calibration and groove fitting on a standard groove sample processed via glass grinding and with a reference depth of 66.14 μm. The experimental results show that depths calculated by the kernel-based calibration algorithm have higher accuracy and lower uncertainty than those ascertained using the conventional polynomial algorithm. As such, this indicates that the proposed algorithm provides effective improvements.

Indexed as

chromatic confocal line sensorsgroove fittingkernel methodwavelength calibration

Identifiers

PMID39460129
PMCPMC11510888

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.