ArticleSensors (Basel, Switzerland)2024
Development and Validation of a Portable EIT System for Real-Time Respiratory Monitoring.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
This work contributes to the improvement of novel medical technologies for the prevention and treatment of diseases. Electrical impedance tomography (EIT) has gained attention as a valuable tool for non-invasive monitoring providing real-time insights. The purpose of this work is to develop and validate a novel portable EIT system with a small form factor for respiratory monitoring. The device uses a 16-electrode architecture with adjacent stimulation and measurement patterns, an integrated circuit current source and a single high-speed ADC operating with multiplexers to stimulate and measure across all electrodes. Tests were conducted on 25 healthy subjects who performed a pulmonary function test with a flowmeter while using the EIT device. The results showed a good performance of the device, which was able to recognize all respirations correctly, and from the EIT signals and images, correlations of 96.7% were obtained for instantaneous respiratory rate and 96.1% for tidal volume prediction. These results validate the preliminary technical feasibility of the EIT system and demonstrates its potential as a reliable tool for non-invasive respiratory assessment. The significance of this work lies in its potential to democratize advanced respiratory monitoring technologies, making them accessible to a wider population, including those in remote or underserved areas.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.