ArticleMicromachines2024
Research on Spatial Localization Method of Magnetic Nanoparticle Samples Based on Second Harmonic Waves.
Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
Existing magnetic tracer detection systems primarily rely on fundamental wave signal acquisition using non-differential sensor configurations. These sensors are highly susceptible to external interference and lack tomographic localization capabilities, hindering their clinical application. To address these limitations, this paper presents a novel method for achieving the deep spatial localization of tracers. The method exploits second harmonic signal detection at non-zero field points. By considering the combined nonlinear characteristics of the coil's axial spatial magnetic field distribution and the Langevin function, a correlation model linking the signal peak and bias field is established. This model enables the determination of the tracer's precise spatial location. Building on this framework, a handheld device for localizing magnetic nanoparticle tracers was developed. The device harnesses the second harmonic response generated by coupling an AC excitation field with a DC bias field. Our findings demonstrate that under conditions of reduced coil turns and weak excitation fields, the DC bias field exhibits exclusive dependence on the axial distance of the detection point, independent of particle concentration. This implies that the saturated DC bias field corresponding to the second harmonic signal can be used to determine the magnetic nanoparticle sample detection depth. The experimental results validated the method's high accuracy, with axial detection distance and concentration reduction errors of only 4.8% and 4.1%, respectively. This research paves the way for handheld probes capable of tomographic tracer detection, offering a novel approach for advancing magnetically sensitive biomedical detection technologies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.