Evidence map›Paper›PMID 39453267›Full record

ArticleTropical medicine and infectious disease2024

Field-Applicable Loop-Mediated Isothermal Amplification for the Detection of Seven Common Human Papillomavirus Subtypes.

Hongyi Li, He Tan, Xiaona Lv, Zhiqiang Han, Yuxin Wang, Shijue Gao, Ruiqin Zhang, Xinxin Shen, Xuejun Ma, Yanqing Tie

Abstract read
In one paragraph

Article in Tropical medicine and infectious disease, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hongyi LiGraduate School, Hebei North University, Zhangjiakou 075000, China.ORCID 0009-0009-4136-2757
He TanDepartment of Clinical Laboratory, Hebei General Hospital, Shijiazhuang 050057, China.
Xiaona LvGraduate School, Hebei North University, Zhangjiakou 075000, China.
Zhiqiang HanGraduate School, Hebei Medical University, Shijiazhuang 050011, China.
Yuxin WangGraduate School, Hebei Medical University, Shijiazhuang 050011, China.
Shijue GaoNational Key Laboratory of Intelligent Tracking and Forecasting for Infectious Diseases, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China.
Ruiqin ZhangNational Key Laboratory of Intelligent Tracking and Forecasting for Infectious Diseases, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China.
Xinxin ShenNational Key Laboratory of Intelligent Tracking and Forecasting for Infectious Diseases, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China.
Xuejun MaNational Key Laboratory of Intelligent Tracking and Forecasting for Infectious Diseases, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China.ORCID 0000-0001-5891-5260
Yanqing TieDepartment of Clinical Laboratory, Hebei General Hospital, Shijiazhuang 050057, China.

Funding

Ministry of Finance of the People's Republic of China 2021YFC2301102National Natural Science Foundation of China 82202593
6 · The paper itself

Abstract

Persistent HPV infection is a major risk factor for the subsequent development of cervical cancer. LAMP is simple and suitable for field detection in the resource-limited settings. In this study, hydroxy naphthol blue (HNB)-based visual LAMP and evagreen-based fluorescent LAMP coupled with a microfluidic chip (LAMP-chip) were established for the field detection of seven subtypes of HPV. The analytical sensitivity was 19-233 copies/reaction. The overall clinical sensitivity was 97.35% for visual LAMP and 98.23% for LAMP-chip. Both LAMP assays exhibited 100% specificity and were completed in less than 50 min. Additionally, both assays did not require complicated nucleic acid extraction and purification steps. A complete quality control monitoring system (including internal control, positive quality control and negative control) in the LAMP assays further ensured the credibility of the results. Our findings demonstrated that the proposed LAMP assays have the potential to be applied in the testing of common HPV DNA in field investigations (visual LAMP) or within communities and primary health centers (LAMP-chip).

Indexed as

genotypingHPV (human papillomavirus)LAMP (loop-mediated isothermal amplification)microfluidic chips

Identifiers

PMID39453267
PMCPMC11511265

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.