Evidence map›Paper›PMID 39452979›Full record

ArticleNanomaterials (Basel, Switzerland)2024

Size-Sorted Superheated Nanodroplets for Dosimetry and Range Verification of Carbon-Ion Radiotherapy.

Yosra Toumia, Marco Pullia, Fabio Domenici, Alessio Mereghetti, Simone Savazzi, Michele Ferrarini, Angelica Facoetti, Gaio Paradossi

Abstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yosra ToumiaNational Institute for Nuclear Physics (INFN), sez. Roma Tor Vergata, 00133 Rome, Italy.ORCID 0000-0001-7604-3144
Marco PulliaFondazione CNAO, National Center for Oncological Hadrontherapy, 27100 Pavia, Italy.ORCID 0000-0003-1851-431X
Fabio DomeniciNational Institute for Nuclear Physics (INFN), sez. Roma Tor Vergata, 00133 Rome, Italy.ORCID 0000-0001-6776-2737
Alessio MereghettiFondazione CNAO, National Center for Oncological Hadrontherapy, 27100 Pavia, Italy.ORCID 0000-0002-0586-257X
Simone SavazziFondazione CNAO, National Center for Oncological Hadrontherapy, 27100 Pavia, Italy.
Michele FerrariniFondazione CNAO, National Center for Oncological Hadrontherapy, 27100 Pavia, Italy.
Angelica FacoettiFondazione CNAO, National Center for Oncological Hadrontherapy, 27100 Pavia, Italy.ORCID 0000-0001-8215-9258
Gaio ParadossiNational Institute for Nuclear Physics (INFN), sez. Roma Tor Vergata, 00133 Rome, Italy.ORCID 0000-0003-3051-3811

Funding

INFN, CSN5 Young Research Grant for DIDO project
6 · The paper itself

Abstract

Nanodroplets have demonstrated potential for the range detection of hadron radiotherapies. Our formulation uses superheated perfluorobutane (C4F10) stabilized by a poly(vinyl-alcohol) shell. High-LET (linear energy transfer) particles vaporize the nanodroplets into echogenic microbubbles. Tailored ultrasound imaging translates the generated echo-contrast into a dose distribution map, enabling beam range retrieval. This work evaluates the response of size-sorted nanodroplets to carbon-ion radiation. We studied how thesize of nanodroplets affects their sensitivity at various beam-doses and energies, as a function of concentration and shell cross-linking. First, we show the physicochemical characterization of size-isolated nanodroplets by differential centrifugation. Then, we report on the irradiations of the nanodroplet samples in tissue-mimicking phantoms. We compared the response of large (≈900 nm) and small (≈400 nm) nanodroplets to different carbon-ions energies and evaluated their dose linearity and concentration detection thresholds by ultrasound imaging. Additionally, we verified the beam range detection accuracy for the nanodroplets samples. All nanodroplets exhibited sensitivity to carbon-ions with high range verification precision. However, smaller nanodroplets required a higher concentration sensitivity threshold. The vaporization yield depends on the carbon-ions energy and dose, which are both related to particle count/spot. These findings confirm the potential of nanodroplets for range detection, with performance depending on nanodroplets' properties and beam parameters.

Indexed as

carbon-ions radiotherapydosimetrynanodropletsrange verificationultrasound imaging

Identifiers

PMID39452979
PMCPMC11509999

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.