Evidence map›Paper›PMID 39451163›Full record

SynthesisAnaesthesiology intensive therapy2024

Superior vena cava collapsibility index as a predictor of fluid responsiveness: a systematic review with meta-analysis.

Tomasz Królicki, Maciej Molsa, Andrzej Tukiendorf, Ryszard Gawda, Tomasz Czarnik

Abstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in Anaesthesiology intensive therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Tomasz KrólickiDepartment of Anesthesiology and Intensive Care, Institute of Medical Sciences, University of Opole, Poland.
Maciej MolsaDepartment of Anesthesiology and Intensive Care, Institute of Medical Sciences, University of Opole, Poland.
Andrzej TukiendorfInstitute of Health Sciences, University of Opole, Poland.
Ryszard GawdaDepartment of Anesthesiology and Intensive Care, Institute of Medical Sciences, University of Opole, Poland.
Tomasz CzarnikDepartment of Anesthesiology and Intensive Care, Institute of Medical Sciences, University of Opole, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe superior vena cava collapsibility index (SVC-CI) is a potential marker of fluid responsiveness (FR) in mechanically ventilated patients. Few studies reporting its diagnostic performance are currently available. MATERIAL AND

methodsA systematic search, using the PRISMA approach, was performed using the Medline and EMBASE databases. Prospective studies evaluating the SVC-CI as a marker of FR in ventilated adult patients were included. A bivariate random-effect model was utilised to generate the summary receiver operating characteristic (SROC) curve. The area under the ROC curve (AUC), the sensitivity and specificity of the curve operating point were calculated.

resultsWe included eight studies with a total of 857 patients, in whom SVC-CI was evaluated a total of 1083 times prior to the volume expansion trial. In 609 (56.23%) trial cases FR was present. The SROC curve demonstrated that the test's operating point has a sensitivity and specificity of 80.8% (95% CI: 66.3-90%) and 81.4% (95% CI: 76.4-85.5%), respectively. The model's AUC was equal to 0.848 (95% CI: 0.824-0.863) with P < 0.001. No significant inter-study heterogeneity was found (I 2 = 0%). A subgroup analysis revealed a significantly lower sensitivity of SVC-CI in patients with higher levels of positive end-expiratory pressure (PEEP) (> 5 cm H 2 O) (χ 2 = 7.753, df = 2, P = 0.0207). The study setting and type of intervention for volume expansion did not significantly change the performance of the test.

conclusionsSVC-CI is a reliable predictor of FR for mechanically ventilated patients in intensive care units and operating rooms. A PEEP level exceeding 5 cm H 2 O may impair the sensitivity of the test.

Indexed as

Fluid TherapyRespiration, ArtificialVena Cava, SuperiorHumansSensitivity and Specificityechocardiographyfluid responsivenessfluid therapysuperior vena cavasuperior vena cava collapsibility

Identifiers

PMID39451163
PMCPMC11484487

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked