Evidence map›Paper›PMID 39449758›Full record

ArticleIEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation2024

Exploring the Needle Tip Interaction Force with Retinal Tissue Deformation in Vitreoretinal Surgery.

Simon Pannek, Shervin Dehghani, Michael Sommersperger, Peiyao Zhang, Peter Gehlbach, M Ali Nasseri, Iulian Iordachita, Nassir Navab

Abstract read
In one paragraph

Article in IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Deep Learning-Enhanced Robotic Subretinal Injection with Real-Time Retinal Motion Compensation.IEEE International Conference on Automation Science and Engineering (CASE) : [proceedings]. IEEE Conference on Automation Science and Engineering · 2025
    Article
  2. Real-time Deformation-aware Control for Autonomous Robotic Subretinal Injection under iOCT Guidance.IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation · 2025
    Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Simon PannekDepartment of Computer Science, Technische Universität München, München 85748 Germany.
Shervin DehghaniDepartment of Computer Science, Technische Universität München, München 85748 Germany.
Michael SommerspergerDepartment of Computer Science, Technische Universität München, München 85748 Germany.
Peiyao ZhangLaboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD, USA.
Peter GehlbachWilmer Eye Institute, Johns Hopkins Hospital, Baltimore, MD, USA.
M Ali NasseriDepartment of Computer Science, Technische Universität München, München 85748 Germany.
Iulian IordachitaLaboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD, USA.
Nassir NavabAided Medical Procedures & Augmented Reality, Technical University of Munich, 85748 Munich, Germany; Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, USA.

Funding

Enabling Technology for Safe Robot-assisted Surgical MicromanipulationR01EB023943 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI GEHLBACH, PETER LOUIS, IORDACHITA, IULIAN IOAN · 2017 to 2024
$2.3M
Enabling technology for image-guided robot-assisted sub-retinal injectionsR01EB025883 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI IORDACHITA, IULIAN IOAN · 2019 to 2021
$1.5M
NIBIB NIH HHS R01 EB023943NIBIB NIH HHS R01 EB025883
6 · The paper itself

Abstract

Recent advancements in age-related macular degeneration treatments necessitate precision delivery into the subretinal space, emphasizing minimally invasive procedures targeting the retinal pigment epithelium (RPE)-Bruch's membrane complex without causing trauma. Even for skilled surgeons, the inherent hand tremors during manual surgery can jeopardize the safety of these critical interventions. This has fostered the evolution of robotic systems designed to prevent such tremors. These robots are enhanced by FBG sensors, which sense the small force interactions between the surgical instruments and retinal tissue. To enable the community to design algorithms taking advantage of such force feedback data, this paper focuses on the need to provide a specialized dataset, integrating optical coherence tomography (OCT) imaging together with the aforementioned force data. We introduce a unique dataset, integrating force sensing data synchronized with OCT B-scan images, derived from a sophisticated setup involving robotic assistance and OCT integrated microscopes. Furthermore, we present a neural network model for image-based force estimation to demonstrate the dataset's applicability.

Indexed as

Data Sets for Robotic VisionData Sets for Robot LearningMedical Robots and Systems

Identifiers

PMID39449758
PMCPMC11501085

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.