ReviewPathophysiology : the official journal of the International Society for Pathophysiology2024
Pathophysiology and Prevention of Manual-Ventilation-Induced Lung Injury (MVILI).
Review in Pathophysiology : the official journal of the International Society for Pathophysiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Influence of different airway devices on intra-arrest ventilation during bag-valve-device ventilation - a prospective randomized controlled cadaver study.Critical care (London, England) · 2025Trial
- Comparison of bag-valve-device ventilation and volume-controlled ventilation with laryngeal tube evo in intra-arrest ventilation-a prospective randomized study in human body donors.Journal of anesthesia, analgesia and critical care · 2026Article
- Agreement and Reliability of a Newly Developed Tidal Volume Monitoring Device in Bag-Valve Ventilation and Intubation Scenarios: A Simulation-Based Study.Bioengineering (Basel, Switzerland) · 2026Article
- Performance of a novel modified bag-valve-mask ventilation technique during manual ventilation and cardiopulmonary resuscitation: a randomized crossover manikin study.Resuscitation plus · 2026Article
- Comparison of two-lung ventilation with CO₂ artificial pneumothorax and one-lung ventilation during esophagectomy: a retrospective cohort study.BMC anesthesiology · 2026Article
- Manikin-based noninferiority simulation study of Airgency™: A novel automatic bag valve mask device for emergency respiratory support.Turkish journal of emergency medicineArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Manual ventilation, most commonly with a bag-valve mask, is a form of short-term ventilation used during resuscitative efforts in emergent and out-of-hospital scenarios. However, compared to mechanical ventilation, manual ventilation is an operator-dependent skill that is less well controlled and is highly subject to providing inappropriate ventilation to the patient. This article first reviews recent manual ventilation guidelines set forth by the American Heart Association and European Resuscitation Council for providing appropriate manual ventilation parameters (e.g., tidal volume and respiratory rate) in different patient populations in the setting of cardiopulmonary resuscitation. There is then a brief review of clinical and manikin-based studies that demonstrate healthcare providers routinely hyperventilate patients during manual ventilation, particularly in emergent scenarios. A discussion of the possible mechanisms of injury that can occur during inappropriate manual hyperventilation follows, including adverse hemodynamic alterations and lung injury such as acute barotrauma, gastric regurgitation and aspiration, and the possibility of a subacute, inflammatory-driven lung injury. Together, these injurious processes are described as manual-ventilation-induced lung injury (MVILI). This review concludes with a discussion that highlights recent progress in techniques and technologies for minimizing manual hyperventilation and MVILI, with a particular emphasis on tidal-volume feedback devices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.