ArticleSe pu = Chinese journal of chromatography2024
[Preparation of fluorescent carbon dots by flow-assisted melt polymerization for tetracycline detection in medical wastewater].
Article in Se pu = Chinese journal of chromatography, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Development of a Green-Synthesized WA-CDs@MIL-101 Fluorescent Sensor for Rapid Detection ofPlants (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Tetracycline (TC) is one of the most important therapeutic drugs that is widely used in hospitals. However, its harmful effects on human health and various ecosystems cannot be ignored. Owing to its poor metabolic activity and low biodegradability, TC commonly discharges as the parent compound and accumulates readily in sludges and soils by precipitation from wastewater, which can induce the evolution of antibiotic-resistant bacteria; therefore, it has been listed as one of the new pollutants with potential ecotoxicological risk. The control measures and environmental management of TC pollutants in environmental water samples require precise determination of TC pollutant concentrations. Carbon dots (CDs) are an emerging type of fluorescent material with numerous advantages such as easy preparation, low cost, low toxicity, and good biocompatibility. Consequently, they have attracted widespread attention in the field of TC detection. Herein, we synthesized TE-CDs with good blue-fluorescence performance via flow-assisted melt polymerization using tricarboxylic acid and ethylenediamine as raw precursors. The morphology and structure of the prepared TE-CDs were characterized. The transmission electron microscopy (TEM) results showed that the prepared TE-CDs were well dispersed, with an average diameter of (2.43±0.48) nm. The X-ray diffraction (XRD) results showed that the TE-CDs had an amorphous carbon structure. Infrared spectroscopy and X-ray photoelectron spectroscopy (XPS) characterizations showed that the surface of the TE-CDs was rich in hydrophilic groups, such as amino, hydroxyl, and carboxyl groups, which indicated that TE-CDs had good water solubility and were advantageous for detecting TC in medical wastewater. Subsequently, the optical properties of the TE-CDs were investigated. The fluorescence emission spectra of the TE-CDs were recorded at various excitation wavelengths. The emission spectra of the TE-CDs exhibited excitation wavelength dependence and when the excitation wavelength changes from 300 nm to 400 nm, their fluorescence intensity decreased to varying degrees. The TE-CDs exhibited optimal fluorescence intensity at an excitation wavelength of 368 nm, while the emission wavelength was 448 nm. TC could effectively quench the blue fluorescence of the CDs, and by utilizing this property, the detection of TC concentration could be achieved. After the addition of TC, the fluorescence of the system immediately reached an extreme value, and no significant change was observed within 10 min. An incubation time of 20 s was selected to obtain precise results. Additionally, the TE-CDs exhibited stable fluorescence intensity over a wide pH range. The fluorescence stability of the TE-CDs was investigated, and no significant change in fluorescence intensity was observed after standing for 10 d, indicating that the prepared TE-CDs had excellent fluorescence stability. The fluorescence intensity of the TE-CDs decreased to varying degrees within the range of 2-200 mg/L TC until complete quenching occurred. TC mass concentration in the range of 4-20 mg/L showed a good linear relationship (
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.