Evidence map›Paper›PMID 39449100›Full record

ArticleBMC oral health2024

A modified protocol merging two published techniques for computer guided zygomatic implants surgery: a technical note.

Omar Effat Mokhtar Abouzeid, Ramy M Gaber, Haitham A Maergy, Hossam El-Dien Hany, Karim M Abdelmohsen, Marwa A Elkassaby, Moustafa M Taha

Abstract read
In one paragraph

Article in BMC oral health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Omar Effat Mokhtar AbouzeidOral and Maxillofacial Surgery Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt. OmarEffat@dent.asu.edu.eg.ORCID https://orcid.org/0009-0006-5288-8867
Ramy M GaberOral and Maxillofacial Surgery Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.
Haitham A MaergyPrivate practice, Cairo, Egypt.
Hossam El-Dien HanyOral and Maxillofacial Surgery Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.
Karim M AbdelmohsenOral and Maxillofacial Surgery Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.
Marwa A ElkassabyOral and Maxillofacial Surgery Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.
Moustafa M TahaOral and Maxillofacial Surgery Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesZygomatic implant surgery can be difficult due to the limited intraoperative visibility of the surgical field and the complex anatomy of the zygomatic bone, which could lead to serious complications. This study aims to assess the accuracy of zygomatic implants placement using computer-guided surgical templates. MATERIALS AND

methodsA total of 13 zygomatic implants were placed in four participants. Double-sleeve drill guides were used with the help of computer-guided surgical templates designed with a lateral window. The accuracy was evaluated by measuring the linear deviations regarding the implants' platforms and apices' positions in addition to the angular deviations. Moreover, deviations of both implants from three fixed planes of space were measured.

resultsThe mean linear deviation at platforms was 2.44 mm ± 1.57 and at the apices 2.32 mm ± 1 while the mean angular deviation was 3.6˚ ± 1.92. Differences at the entry points were 0.43 ± 1.79 mm, 0.39 ± 1.12 mm, and - 0.54 ± 2.00 mm from the mid-sagittal, horizontal, and coronal planes respectively. Differences at the exit points were - 0.75 ± 1.25 mm, -0.06 ± 1.09 mm, and 0.63 ± 1.24 mm from the same planes respectively. Within all planes, there was no statistically significant difference.

conclusionGiven the limitations of this study, the use of the computer-guided surgical templates augmented by the double sleeve drill guides allowed favorable control over the tip of the long surgical drill away from vital structures during the zygomatic implant osteotomy. It also allowed control over alveolar crest osteotomy and its placement in a favorable prosthetic position. Overall, this protocol should be considered for further research and improvement to allow more predictable surgical outcomes while preventing the occurrence of complications. Before conducting this study, the protocol was reviewed and approved by the Research Ethical Committee of Faculty of Dentistry, Ain Shams University in meeting no. (105), on 15th of July 2020 with the application no.: (FDASU-RecD072029).

Indexed as

Dental Implantation, EndosseousSurgery, Computer-AssistedZygomaDental ImplantsHumansDental ImplantsComputer guided surgeryDouble sleeve techniqueDrilling guidesZygomatic implants

Identifiers

PMID39449100
PMCPMC11515538

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.