Evidence map›Paper›PMID 39447199›Full record

ArticleJournal of applied clinical medical physics2025

Dosimetric consequences of adapting the craniocaudal isocenter distance to daily patient position in craniospinal irradiation using volumetric modulated arc therapy.

Annele Heikkilä, Antti Vanhanen, Maija Rossi, Tuomas Koivumäki, Michiel Postema, Eeva Boman

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Annele HeikkiläDepartment of Biomedical Technology, Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.ORCID https://orcid.org/0000-0001-5639-8765
Antti VanhanenDepartment of Medical Physics, Tampere University Hospital, Wellbeing Services County of Pirkanmaa, Tampere, Finland.ORCID https://orcid.org/0009-0003-8247-2887
Maija RossiDepartment of Medical Physics, Tampere University Hospital, Wellbeing Services County of Pirkanmaa, Tampere, Finland.ORCID https://orcid.org/0000-0002-7920-2531
Tuomas KoivumäkiDepartment of Medical Physics, Hospital Nova of Central Finland, Wellbeing Services County of Central Finland, Jyväskylä, Finland.ORCID https://orcid.org/0000-0001-8673-7000
Michiel PostemaDepartment of Biomedical Technology, Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.ORCID https://orcid.org/0000-0001-5887-1739
Eeva BomanDepartment of Medical Physics, Tampere University Hospital, Wellbeing Services County of Pirkanmaa, Tampere, Finland.ORCID https://orcid.org/0000-0001-6492-2475

Funding

Tampere University HospitalTampere University Hospital Support FoundationWellbeing services county of Pirkanmaa MK351
6 · The paper itself

Abstract

purposeIn craniospinal irradiation, two or three isocenter groups along the craniocaudal axis are required to cover the long treatment target. Adapting the isocenter distance according to daily deviations in patient position is challenging because dosimetric hot or cold spots may occur in the field junction. The aim of this study was to quantify the effect of adapting the isocenter distance to patient position on the dose distribution of the field overlap region in craniospinal irradiation using partial-arc volumetric modulated arc therapy.

methodsThe magnitude of isocenter distance deviations in craniocaudal direction was quantified by registering the setup images of 204 fractions of 12 patients to the planning images. The dosimetric effect of these deviations was determined by shifting the isocenters of the original treatment plan and calculating the resulting dose distribution.

resultsOn fraction-level, deviations larger than 3 mm caused more than 5 percentage point changes in the doses covering 2% (D

conclusionsCraniocaudal isocenter distance adaptation can be conducted provided that the mean isocenter distance deviation over the treatment course is within 3 mm.

Indexed as

Craniospinal IrradiationOrgans at RiskPatient PositioningRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedAdolescentAdultBrain NeoplasmsChildChild, PreschoolFemaleHumansMalePrognosiscraniospinal radiotherapyjunction setup errorspartial‐arc VMATrobustness of CSI

Identifiers

PMID39447199
PMCPMC11713468

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.