Accuracy of a Smart Diaper System for Nursing Home Residents for Automatically Detecting Voided Volume: Instrument Validation Study.

Jae Heon Kim, Ui Cheol Lee, Byeong Hun Jeong, Byeong Uk Kang, Sung Ryul Shim, In Gab Jeong

Abstract readValidation Study
In one paragraph

Article in JMIR formative research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jae Heon Kim *Department of Urology, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-4490-3610
Ui Cheol Lee *HYGERA Networks Inc, Seoul, Republic of Korea.ORCID 0009-0005-3369-5608
Byeong Hun JeongHYGERA Networks Inc, Seoul, Republic of Korea.ORCID 0009-0009-9734-5972
Byeong Uk KangHYGERA Networks Inc, Seoul, Republic of Korea.ORCID 0009-0006-3627-6027
Sung Ryul Shim *Department of Biomedical Informatics, College of Medicine, Konyang University, Daejeon, Republic of Korea.ORCID 0000-0003-4143-7383
In Gab Jeong *Department of Urology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.ORCID 0000-0003-4093-832X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDiapers are commonly used by older patients with urination disorders. A smart diaper system (SDS) may be able to estimate the weight of urine comparably to conventional measurements made by weighing diapers.

objectiveThe aim of the current research is to determine the degree of accuracy of an SDS technology specifically designed for the management of urination routines and the use of incontinence pads in older adults.

methodsFrom January to December 2022, 97 older patients with at least 1 chronic disease from 3 nursing homes were included. In this study, the SDS was used for 1 month per patient after obtaining their consent; all patients originally used traditional diapers in the nursing home. The index test measured the change in electrical resistance of the SDS and the reference test measured the change in actual urine weight. When measuring the actual urine weight, the degree of absorption was directly confirmed with the naked eye because the expression value varied according to pressure changes caused by the user's movement or position. The Pearson correlation was used to determine the correlation between the 2 test methods, the intraclass correlation coefficient (ICC) was used to check the degree of agreement between the evaluators, and the Bland-Altman test was used to confirm whether there was a significant difference between the 2 test methods.

resultsThe average age of the 97 participants was 86.48 (SD 6.26) years, with 10 men and 87 women. There were 73 patients (75%) with hypertension, 86 patients (88%) with dementia, and 86 patients (88%) with 2 or more comorbidities, accounting for the majority. The Pearson correlation coefficient and ICC were 0.971 and 0.985 (P<.001). In the Bland-Altman figure, the difference in the mean between the 2 tests was evenly scattered without showing a specific pattern, indicating that the SDS and actual urine weight were very consistent. The difference between the mean of the 2 tests was -0.045 of the standardized mean difference, and all measurements were located within the 95% CI, so this confirms that the 2 test methods are equivalent.

conclusionsOur study showed a fairly high correlation coefficient and ICC for all patient groups, which reveals that the 2 tests were very consistent and that the SDS can replace traditional diapers, even in a real clinical setting. This study shows the possibility that heath care professionals could be alerted by the SDS to the need for pad replacement due to incontinence, thus avoiding the development of dermatological complications.

Indexed as

Nursing HomesAgedAged, 80 and overFemaleHumansMaleReproducibility of ResultsUrinationmedical devicenursing homeolder adultssmart diaperurinary incontinenceurine outputvoided volume

Identifiers

PMID39447169
PMCPMC11544336

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.